Experiments with a wire array Z pinch on the inductive storage generator

R. B. Baksht, S. P. Bugaev, I. M. Datsko, A. A. Kim, B. M. Koval'chuk, V. A. Kokshenev, G. A. Mesyats, A. G. Russkich

    Research output: Contribution to journalArticle

    5 Citations (Scopus)

    Abstract

    We report experiments that were carried out at the inductive storage machine GIT-4 with wire arrays. The tungsten wire array parameters were the following: the mass per centimeter was equal to 370 μg/cm, the length was 4 cm, and the initial radius was 0.2 cm. When the wire array current was 1.5 MA, the rise time was 100 ns and the total radiation energy was 50 kJ at the 80-100-kJ energy transferred to the wire array.

    Original languageEnglish
    Pages (from-to)587-593
    Number of pages7
    JournalLaser and Particle Beams
    Volume11
    Issue number3
    Publication statusPublished - 1993

    Fingerprint

    generators
    wire
    Wire
    machine storage
    Experiments
    Tungsten
    tungsten
    Radiation
    radii
    energy
    radiation

    ASJC Scopus subject areas

    • Physics and Astronomy (miscellaneous)
    • Surfaces and Interfaces

    Cite this

    Baksht, R. B., Bugaev, S. P., Datsko, I. M., Kim, A. A., Koval'chuk, B. M., Kokshenev, V. A., ... Russkich, A. G. (1993). Experiments with a wire array Z pinch on the inductive storage generator. Laser and Particle Beams, 11(3), 587-593.

    Experiments with a wire array Z pinch on the inductive storage generator. / Baksht, R. B.; Bugaev, S. P.; Datsko, I. M.; Kim, A. A.; Koval'chuk, B. M.; Kokshenev, V. A.; Mesyats, G. A.; Russkich, A. G.

    In: Laser and Particle Beams, Vol. 11, No. 3, 1993, p. 587-593.

    Research output: Contribution to journalArticle

    Baksht, RB, Bugaev, SP, Datsko, IM, Kim, AA, Koval'chuk, BM, Kokshenev, VA, Mesyats, GA & Russkich, AG 1993, 'Experiments with a wire array Z pinch on the inductive storage generator', Laser and Particle Beams, vol. 11, no. 3, pp. 587-593.
    Baksht RB, Bugaev SP, Datsko IM, Kim AA, Koval'chuk BM, Kokshenev VA et al. Experiments with a wire array Z pinch on the inductive storage generator. Laser and Particle Beams. 1993;11(3):587-593.
    Baksht, R. B. ; Bugaev, S. P. ; Datsko, I. M. ; Kim, A. A. ; Koval'chuk, B. M. ; Kokshenev, V. A. ; Mesyats, G. A. ; Russkich, A. G. / Experiments with a wire array Z pinch on the inductive storage generator. In: Laser and Particle Beams. 1993 ; Vol. 11, No. 3. pp. 587-593.
    @article{97f92b45bbcf486a9b56395fc41f123d,
    title = "Experiments with a wire array Z pinch on the inductive storage generator",
    abstract = "We report experiments that were carried out at the inductive storage machine GIT-4 with wire arrays. The tungsten wire array parameters were the following: the mass per centimeter was equal to 370 μg/cm, the length was 4 cm, and the initial radius was 0.2 cm. When the wire array current was 1.5 MA, the rise time was 100 ns and the total radiation energy was 50 kJ at the 80-100-kJ energy transferred to the wire array.",
    author = "Baksht, {R. B.} and Bugaev, {S. P.} and Datsko, {I. M.} and Kim, {A. A.} and Koval'chuk, {B. M.} and Kokshenev, {V. A.} and Mesyats, {G. A.} and Russkich, {A. G.}",
    year = "1993",
    language = "English",
    volume = "11",
    pages = "587--593",
    journal = "Laser and Particle Beams",
    issn = "0263-0346",
    publisher = "Cambridge University Press",
    number = "3",

    }

    TY - JOUR

    T1 - Experiments with a wire array Z pinch on the inductive storage generator

    AU - Baksht, R. B.

    AU - Bugaev, S. P.

    AU - Datsko, I. M.

    AU - Kim, A. A.

    AU - Koval'chuk, B. M.

    AU - Kokshenev, V. A.

    AU - Mesyats, G. A.

    AU - Russkich, A. G.

    PY - 1993

    Y1 - 1993

    N2 - We report experiments that were carried out at the inductive storage machine GIT-4 with wire arrays. The tungsten wire array parameters were the following: the mass per centimeter was equal to 370 μg/cm, the length was 4 cm, and the initial radius was 0.2 cm. When the wire array current was 1.5 MA, the rise time was 100 ns and the total radiation energy was 50 kJ at the 80-100-kJ energy transferred to the wire array.

    AB - We report experiments that were carried out at the inductive storage machine GIT-4 with wire arrays. The tungsten wire array parameters were the following: the mass per centimeter was equal to 370 μg/cm, the length was 4 cm, and the initial radius was 0.2 cm. When the wire array current was 1.5 MA, the rise time was 100 ns and the total radiation energy was 50 kJ at the 80-100-kJ energy transferred to the wire array.

    UR - http://www.scopus.com/inward/record.url?scp=0027851590&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0027851590&partnerID=8YFLogxK

    M3 - Article

    VL - 11

    SP - 587

    EP - 593

    JO - Laser and Particle Beams

    JF - Laser and Particle Beams

    SN - 0263-0346

    IS - 3

    ER -