    Abstract

    In experiments on GIT4, the scheme with the load connected upstream from the POS was investigated. The load was connected to the generator output through the surface self breaking switch. The current switching into the different inductive loads was tested. It was found that the time the POS is open depends on the value of the load inductance. It was demonstrated also that surface self breaking switch can be applied for switching currents rising at approximately 2·1013 A/s.