Experiments on GIT4 with the load upstream from the POS

A. N. Bastrikov, A. A. Zherlitsin, A. A. Kim, B. M. Kovalchuk, S. V. Loginov, V. P. Yakovlev

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    3 Citations (Scopus)

    Abstract

    In experiments on GIT4, the scheme with the load connected upstream from the POS was investigated. The load was connected to the generator output through the surface self breaking switch. The current switching into the different inductive loads was tested. It was found that the time the POS is open depends on the value of the load inductance. It was demonstrated also that surface self breaking switch can be applied for switching currents rising at approximately 2·1013 A/s.

    Original languageEnglish
    Title of host publicationDigest of Technical Papers-IEEE International Pulsed Power Conference
    Place of PublicationPiscataway, NJ, United States
    PublisherIEEE
    Pages1191-1194
    Number of pages4
    Volume2
    Publication statusPublished - 1999
    Event12th IEEE International Pulsed Power Conference - Monterey, CA, USA
    Duration: 27 Jun 199930 Jun 1999

    Other

    Other12th IEEE International Pulsed Power Conference
    CityMonterey, CA, USA
    Period27.6.9930.6.99

    Fingerprint

    Switches
    Inductance
    Experiments

    ASJC Scopus subject areas

    • Electrical and Electronic Engineering

    Cite this

    Bastrikov, A. N., Zherlitsin, A. A., Kim, A. A., Kovalchuk, B. M., Loginov, S. V., & Yakovlev, V. P. (1999). Experiments on GIT4 with the load upstream from the POS. In Digest of Technical Papers-IEEE International Pulsed Power Conference (Vol. 2, pp. 1191-1194). Piscataway, NJ, United States: IEEE.

    Experiments on GIT4 with the load upstream from the POS. / Bastrikov, A. N.; Zherlitsin, A. A.; Kim, A. A.; Kovalchuk, B. M.; Loginov, S. V.; Yakovlev, V. P.

    Digest of Technical Papers-IEEE International Pulsed Power Conference. Vol. 2 Piscataway, NJ, United States : IEEE, 1999. p. 1191-1194.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Bastrikov, AN, Zherlitsin, AA, Kim, AA, Kovalchuk, BM, Loginov, SV & Yakovlev, VP 1999, Experiments on GIT4 with the load upstream from the POS. in Digest of Technical Papers-IEEE International Pulsed Power Conference. vol. 2, IEEE, Piscataway, NJ, United States, pp. 1191-1194, 12th IEEE International Pulsed Power Conference, Monterey, CA, USA, 27.6.99.
    Bastrikov AN, Zherlitsin AA, Kim AA, Kovalchuk BM, Loginov SV, Yakovlev VP. Experiments on GIT4 with the load upstream from the POS. In Digest of Technical Papers-IEEE International Pulsed Power Conference. Vol. 2. Piscataway, NJ, United States: IEEE. 1999. p. 1191-1194
    Bastrikov, A. N. ; Zherlitsin, A. A. ; Kim, A. A. ; Kovalchuk, B. M. ; Loginov, S. V. ; Yakovlev, V. P. / Experiments on GIT4 with the load upstream from the POS. Digest of Technical Papers-IEEE International Pulsed Power Conference. Vol. 2 Piscataway, NJ, United States : IEEE, 1999. pp. 1191-1194
    @inproceedings{66867916343842c79111c0fedae6d6df,
    title = "Experiments on GIT4 with the load upstream from the POS",
    abstract = "In experiments on GIT4, the scheme with the load connected upstream from the POS was investigated. The load was connected to the generator output through the surface self breaking switch. The current switching into the different inductive loads was tested. It was found that the time the POS is open depends on the value of the load inductance. It was demonstrated also that surface self breaking switch can be applied for switching currents rising at approximately 2·1013 A/s.",
    author = "Bastrikov, {A. N.} and Zherlitsin, {A. A.} and Kim, {A. A.} and Kovalchuk, {B. M.} and Loginov, {S. V.} and Yakovlev, {V. P.}",
    year = "1999",
    language = "English",
    volume = "2",
    pages = "1191--1194",
    booktitle = "Digest of Technical Papers-IEEE International Pulsed Power Conference",
    publisher = "IEEE",

    }

    TY - GEN

    T1 - Experiments on GIT4 with the load upstream from the POS

    AU - Bastrikov, A. N.

    AU - Zherlitsin, A. A.

    AU - Kim, A. A.

    AU - Kovalchuk, B. M.

    AU - Loginov, S. V.

    AU - Yakovlev, V. P.

    PY - 1999

    Y1 - 1999

    N2 - In experiments on GIT4, the scheme with the load connected upstream from the POS was investigated. The load was connected to the generator output through the surface self breaking switch. The current switching into the different inductive loads was tested. It was found that the time the POS is open depends on the value of the load inductance. It was demonstrated also that surface self breaking switch can be applied for switching currents rising at approximately 2·1013 A/s.

    AB - In experiments on GIT4, the scheme with the load connected upstream from the POS was investigated. The load was connected to the generator output through the surface self breaking switch. The current switching into the different inductive loads was tested. It was found that the time the POS is open depends on the value of the load inductance. It was demonstrated also that surface self breaking switch can be applied for switching currents rising at approximately 2·1013 A/s.

    UR - http://www.scopus.com/inward/record.url?scp=0033342837&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0033342837&partnerID=8YFLogxK

    M3 - Conference contribution

    AN - SCOPUS:0033342837

    VL - 2

    SP - 1191

    EP - 1194

    BT - Digest of Technical Papers-IEEE International Pulsed Power Conference

    PB - IEEE

    CY - Piscataway, NJ, United States

    ER -