Excluding the effect of nonuniformity of the motion velocity in measurement of the length of ferromagnetic samples by the magnetic-label method

Research output: Contribution to journalArticle

Abstract

The causes and the character of the effect of sample motion velocity on results of the measurement of ferromagnetic sample length by using the magnetic-label technique are discussed. A method to decrease this dependence by correcting the measurement base length depending on velocity is proposed. The method ensures a high precision of measurements for a short base length in a wide range of velocities.

Original languageEnglish
Pages (from-to)782-786
Number of pages5
JournalRussian Journal of Nondestructive Testing
Volume44
Issue number11
DOIs
Publication statusPublished - Nov 2008

Fingerprint

nonuniformity
Labels
causes

ASJC Scopus subject areas

  • Mechanical Engineering
  • Mechanics of Materials
  • Materials Science(all)
  • Condensed Matter Physics

Cite this

@article{205e77c25ef04bf880debb4ce1d8d32b,
title = "Excluding the effect of nonuniformity of the motion velocity in measurement of the length of ferromagnetic samples by the magnetic-label method",
abstract = "The causes and the character of the effect of sample motion velocity on results of the measurement of ferromagnetic sample length by using the magnetic-label technique are discussed. A method to decrease this dependence by correcting the measurement base length depending on velocity is proposed. The method ensures a high precision of measurements for a short base length in a wide range of velocities.",
author = "Gol'dshtein, {A. E.} and Urazbekov, {E. I.}",
year = "2008",
month = "11",
doi = "10.1134/S1061830908110065",
language = "English",
volume = "44",
pages = "782--786",
journal = "Russian Journal of Nondestructive Testing",
issn = "1061-8309",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "11",

}

TY - JOUR

T1 - Excluding the effect of nonuniformity of the motion velocity in measurement of the length of ferromagnetic samples by the magnetic-label method

AU - Gol'dshtein, A. E.

AU - Urazbekov, E. I.

PY - 2008/11

Y1 - 2008/11

N2 - The causes and the character of the effect of sample motion velocity on results of the measurement of ferromagnetic sample length by using the magnetic-label technique are discussed. A method to decrease this dependence by correcting the measurement base length depending on velocity is proposed. The method ensures a high precision of measurements for a short base length in a wide range of velocities.

AB - The causes and the character of the effect of sample motion velocity on results of the measurement of ferromagnetic sample length by using the magnetic-label technique are discussed. A method to decrease this dependence by correcting the measurement base length depending on velocity is proposed. The method ensures a high precision of measurements for a short base length in a wide range of velocities.

UR - http://www.scopus.com/inward/record.url?scp=62649096775&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=62649096775&partnerID=8YFLogxK

U2 - 10.1134/S1061830908110065

DO - 10.1134/S1061830908110065

M3 - Article

AN - SCOPUS:62649096775

VL - 44

SP - 782

EP - 786

JO - Russian Journal of Nondestructive Testing

JF - Russian Journal of Nondestructive Testing

SN - 1061-8309

IS - 11