This article presents test results of enameled winding wires, characterizing an insulation electrical and mechanical strength. Standard and original test methods were used. Note that existing standard test methods do not estimate enamel insulation resistance to the electrical loads under winding operation of variable-speed drive. We show that estimation of wire corona resistance can be done by high frequency electrical impulse testing. Wire insulation plays the main role of reliability of insulation system.

Original languageEnglish
Article number012004
JournalIOP Conference Series: Materials Science and Engineering
Volume66
Issue number1
DOIs
Publication statusPublished - 2014

Fingerprint

Insulation
Wire
Impulse testing
Variable speed drives
Enamels
Strength of materials

ASJC Scopus subject areas

  • Engineering(all)
  • Materials Science(all)

Cite this

Estimation of winding insulation resistance to the corona discharges. / Leonov, A.; Redko, V.; Soldatenko, E.

In: IOP Conference Series: Materials Science and Engineering, Vol. 66, No. 1, 012004, 2014.

Research output: Contribution to journalArticle

@article{0ad69592f1664092839554ed627947a2,
title = "Estimation of winding insulation resistance to the corona discharges",
abstract = "This article presents test results of enameled winding wires, characterizing an insulation electrical and mechanical strength. Standard and original test methods were used. Note that existing standard test methods do not estimate enamel insulation resistance to the electrical loads under winding operation of variable-speed drive. We show that estimation of wire corona resistance can be done by high frequency electrical impulse testing. Wire insulation plays the main role of reliability of insulation system.",
author = "A. Leonov and V. Redko and E. Soldatenko",
year = "2014",
doi = "10.1088/1757-899X/66/1/012004",
language = "English",
volume = "66",
journal = "IOP Conference Series: Materials Science and Engineering",
issn = "1757-8981",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - Estimation of winding insulation resistance to the corona discharges

AU - Leonov, A.

AU - Redko, V.

AU - Soldatenko, E.

PY - 2014

Y1 - 2014

N2 - This article presents test results of enameled winding wires, characterizing an insulation electrical and mechanical strength. Standard and original test methods were used. Note that existing standard test methods do not estimate enamel insulation resistance to the electrical loads under winding operation of variable-speed drive. We show that estimation of wire corona resistance can be done by high frequency electrical impulse testing. Wire insulation plays the main role of reliability of insulation system.

AB - This article presents test results of enameled winding wires, characterizing an insulation electrical and mechanical strength. Standard and original test methods were used. Note that existing standard test methods do not estimate enamel insulation resistance to the electrical loads under winding operation of variable-speed drive. We show that estimation of wire corona resistance can be done by high frequency electrical impulse testing. Wire insulation plays the main role of reliability of insulation system.

UR - http://www.scopus.com/inward/record.url?scp=84907781863&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84907781863&partnerID=8YFLogxK

U2 - 10.1088/1757-899X/66/1/012004

DO - 10.1088/1757-899X/66/1/012004

M3 - Article

VL - 66

JO - IOP Conference Series: Materials Science and Engineering

JF - IOP Conference Series: Materials Science and Engineering

SN - 1757-8981

IS - 1

M1 - 012004

ER -