Estimation of the sensitivity in dual wave X-ray absorptiometry

Research output: Contribution to journalArticle

Abstract

Dual wave X-ray absorptiometry is considered theoretically and the application of suggested technique extends to the multiphase flow analysis. Proposed method allows for specifying dynamically the percentage of fluid components with the resolution as high as 0.25% (according to the mathematical simulating). The accuracy of this measurement is one order higher by magnitude than that provided by the state of the art flow analyzing devices.

Original languageEnglish
Article number012032
JournalJournal of Physics: Conference Series
Volume732
Issue number1
DOIs
Publication statusPublished - 3 Aug 2016

Fingerprint

multiphase flow
fluids
sensitivity
x rays

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

@article{d46bf5d8df354b2c8321fe5a33d5f501,
title = "Estimation of the sensitivity in dual wave X-ray absorptiometry",
abstract = "Dual wave X-ray absorptiometry is considered theoretically and the application of suggested technique extends to the multiphase flow analysis. Proposed method allows for specifying dynamically the percentage of fluid components with the resolution as high as 0.25{\%} (according to the mathematical simulating). The accuracy of this measurement is one order higher by magnitude than that provided by the state of the art flow analyzing devices.",
author = "A. Gogolev and R. Rezaev and Cherepennikov, {Yuriy Mikhaylovich} and A. Vukolov and T. Gogoleva",
year = "2016",
month = "8",
day = "3",
doi = "10.1088/1742-6596/732/1/012032",
language = "English",
volume = "732",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - Estimation of the sensitivity in dual wave X-ray absorptiometry

AU - Gogolev, A.

AU - Rezaev, R.

AU - Cherepennikov, Yuriy Mikhaylovich

AU - Vukolov, A.

AU - Gogoleva, T.

PY - 2016/8/3

Y1 - 2016/8/3

N2 - Dual wave X-ray absorptiometry is considered theoretically and the application of suggested technique extends to the multiphase flow analysis. Proposed method allows for specifying dynamically the percentage of fluid components with the resolution as high as 0.25% (according to the mathematical simulating). The accuracy of this measurement is one order higher by magnitude than that provided by the state of the art flow analyzing devices.

AB - Dual wave X-ray absorptiometry is considered theoretically and the application of suggested technique extends to the multiphase flow analysis. Proposed method allows for specifying dynamically the percentage of fluid components with the resolution as high as 0.25% (according to the mathematical simulating). The accuracy of this measurement is one order higher by magnitude than that provided by the state of the art flow analyzing devices.

UR - http://www.scopus.com/inward/record.url?scp=84987720203&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84987720203&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/732/1/012032

DO - 10.1088/1742-6596/732/1/012032

M3 - Article

VL - 732

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 1

M1 - 012032