Estimation of resolvability of the digital X ray radiography systems

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Combination of high spatial resolvability of a radiographic film with the wide possibilities of digital data processing enables one to design radiographic systems of nondestructive control including a computer and a plutonium display. An expression is obtained for maximum value of spatial resolvability of the digital X ray radiography systems in the frames of accepted assumptions.

Original languageEnglish
Pages (from-to)113-116
Number of pages4
JournalAvtometriya
Issue number6
Publication statusPublished - 2000

Fingerprint

X ray radiography
Plutonium
Display devices

ASJC Scopus subject areas

  • Software
  • Control and Systems Engineering

Cite this

Estimation of resolvability of the digital X ray radiography systems. / Udod, Victor Anatolievich; Temnik, A. K.; Solodushkin, V. I.

In: Avtometriya, No. 6, 2000, p. 113-116.

Research output: Contribution to journalArticle

@article{25aeff775d144039beedaf4cae1aa4a4,
title = "Estimation of resolvability of the digital X ray radiography systems",
abstract = "Combination of high spatial resolvability of a radiographic film with the wide possibilities of digital data processing enables one to design radiographic systems of nondestructive control including a computer and a plutonium display. An expression is obtained for maximum value of spatial resolvability of the digital X ray radiography systems in the frames of accepted assumptions.",
author = "Udod, {Victor Anatolievich} and Temnik, {A. K.} and Solodushkin, {V. I.}",
year = "2000",
language = "English",
pages = "113--116",
journal = "Avtometriya",
issn = "0320-7102",
publisher = "Izdatel'stvo Sibirskoe Otdelenie Rossiiskoi Akademii Nauk",
number = "6",

}

TY - JOUR

T1 - Estimation of resolvability of the digital X ray radiography systems

AU - Udod, Victor Anatolievich

AU - Temnik, A. K.

AU - Solodushkin, V. I.

PY - 2000

Y1 - 2000

N2 - Combination of high spatial resolvability of a radiographic film with the wide possibilities of digital data processing enables one to design radiographic systems of nondestructive control including a computer and a plutonium display. An expression is obtained for maximum value of spatial resolvability of the digital X ray radiography systems in the frames of accepted assumptions.

AB - Combination of high spatial resolvability of a radiographic film with the wide possibilities of digital data processing enables one to design radiographic systems of nondestructive control including a computer and a plutonium display. An expression is obtained for maximum value of spatial resolvability of the digital X ray radiography systems in the frames of accepted assumptions.

UR - http://www.scopus.com/inward/record.url?scp=0034588094&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034588094&partnerID=8YFLogxK

M3 - Article

SP - 113

EP - 116

JO - Avtometriya

JF - Avtometriya

SN - 0320-7102

IS - 6

ER -