Abstract
The results of study of the electric strength, tanδ and partial discharge parameters in PET film insulation with different thickness are represented in this paper. It was established that the mechanism of a polymeric films breakdown has ionization nature due to the fringing effect and non-ideal contact between electrodes and dielectric. The experimental results of study of the ignition voltage of critical partial discharges which can result in both the destruction of polymeric films and sharp decrease of the Q-factor are presented in this paper.
Original language | English |
---|---|
Title of host publication | Proceedings - 9th Russian-Korean International Symposium on Science and Technology, KORUS-2005 |
Pages | 143-146 |
Number of pages | 4 |
Volume | 1 |
DOIs | |
Publication status | Published - 2005 |
Event | 9th Russian-Korean International Symposium on Science and Technology, KORUS-2005 - Novosibirsk, Russian Federation Duration: 26 Jun 2005 → 2 Jul 2005 |
Other
Other | 9th Russian-Korean International Symposium on Science and Technology, KORUS-2005 |
---|---|
Country | Russian Federation |
City | Novosibirsk |
Period | 26.6.05 → 2.7.05 |
ASJC Scopus subject areas
- Engineering(all)