Estimation of critical parameters of PET film insulation

O. S. Gefle, S. M. Lebedev, V. A. Volokhin, S. N. Tkachenko, E. I. Cherkashina

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The results of study of the electric strength, tanδ and partial discharge parameters in PET film insulation with different thickness are represented in this paper. It was established that the mechanism of a polymeric films breakdown has ionization nature due to the fringing effect and non-ideal contact between electrodes and dielectric. The experimental results of study of the ignition voltage of critical partial discharges which can result in both the destruction of polymeric films and sharp decrease of the Q-factor are presented in this paper.

Original languageEnglish
Title of host publicationProceedings - 9th Russian-Korean International Symposium on Science and Technology, KORUS-2005
Pages143-146
Number of pages4
Volume1
DOIs
Publication statusPublished - 2005
Event9th Russian-Korean International Symposium on Science and Technology, KORUS-2005 - Novosibirsk, Russian Federation
Duration: 26 Jun 20052 Jul 2005

Other

Other9th Russian-Korean International Symposium on Science and Technology, KORUS-2005
CountryRussian Federation
CityNovosibirsk
Period26.6.052.7.05

ASJC Scopus subject areas

  • Engineering(all)

Fingerprint Dive into the research topics of 'Estimation of critical parameters of PET film insulation'. Together they form a unique fingerprint.

  • Cite this

    Gefle, O. S., Lebedev, S. M., Volokhin, V. A., Tkachenko, S. N., & Cherkashina, E. I. (2005). Estimation of critical parameters of PET film insulation. In Proceedings - 9th Russian-Korean International Symposium on Science and Technology, KORUS-2005 (Vol. 1, pp. 143-146). [1507667] https://doi.org/10.1109/KORUS.2005.1507667