Energy extraction from an oversized cavity through a package of interference switches with summation of the output signals

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

It was shown experimentally that the pulse power output of a resonant microwave compressor with an oversized cavity and an interference switch used for energy extraction could be increased using a package of interference switches with summation of the output signals instead of a single switch. The use of two switches for energy extraction provided an almost twofold increase in the output signal power and a corresponding (almost twofold) decrease in the signal duration. It is shown that energy extraction through four switches with signal summation is possible.

Original languageEnglish
Pages (from-to)1475-1477
Number of pages3
JournalTechnical Physics
Volume45
Issue number11
DOIs
Publication statusPublished - 1 Jan 2000

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)

Fingerprint Dive into the research topics of 'Energy extraction from an oversized cavity through a package of interference switches with summation of the output signals'. Together they form a unique fingerprint.

Cite this