Electrochemical determination of heparin in pharmaceuticals with using malachite green

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

In this paper for determination of heparin in pharmaceuticals by constant-current sweep voltammetry on the mercury-film electrode (MFE) we used cationic malachite green (MG) dye which is capable to form a complex with heparin. In the 0.05 M potassium tetraoxalate (KH3C4O8 · 2H2O) buffer solution with pH 1.65 MG had a well-defined peak of electroreduction at -0.46 V (vs. CSE). During the study of electrochemical properties of heparin in complex with MG in cathodic potential range from 0.0 V to -1.3 V on MFE besides the signal from the dye at E = - 0.46 V the second signal at E = –0.87 V was found. Increasing the concentration of heparin in the solution led to decrease of signal intensity at E = -0.87 V. Optimum conditions for the electrochemical determination of heparin in dosage form with using MG were picked up. Influence of auxiliary components of heparin pharmacological solution on electroreduction of the complex MG-Hep was investigated. Under optimal conditions the decrease of reduction peak currents at E = -0.87 V was proportional to heparin concentration in the range from 3.9 · 10-4 mg/ml to 3.9 · 10-3 mg/ml.

Original languageEnglish
Title of host publicationAdvanced Materials Research
PublisherTrans Tech Publications Ltd
Pages292-296
Number of pages5
Volume1040
ISBN (Print)9783038352648
DOIs
Publication statusPublished - 2014
EventInternational Conference for Young Scientists “High Technology: Research and Applications 2014”, HTRA 2014 - Tomsk, Russian Federation
Duration: 26 Mar 201428 Mar 2014

Publication series

NameAdvanced Materials Research
Volume1040
ISSN (Print)10226680
ISSN (Electronic)16628985

Other

OtherInternational Conference for Young Scientists “High Technology: Research and Applications 2014”, HTRA 2014
CountryRussian Federation
CityTomsk
Period26.3.1428.3.14

Fingerprint

Drug products
Dyes
Electrodes
Voltammetry
Heparin
Electrochemical properties
Potassium

Keywords

  • Electroreduction
  • Heparin
  • Malachite green
  • Mercury-film electrode
  • Voltammetry

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Vishenkova, D. A., Korotkova, E. I., & Dorozhko, E. V. (2014). Electrochemical determination of heparin in pharmaceuticals with using malachite green. In Advanced Materials Research (Vol. 1040, pp. 292-296). (Advanced Materials Research; Vol. 1040). Trans Tech Publications Ltd. https://doi.org/10.4028/www.scientific.net/AMR.1040.292

Electrochemical determination of heparin in pharmaceuticals with using malachite green. / Vishenkova, D. A.; Korotkova, E. I.; Dorozhko, E. V.

Advanced Materials Research. Vol. 1040 Trans Tech Publications Ltd, 2014. p. 292-296 (Advanced Materials Research; Vol. 1040).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Vishenkova, DA, Korotkova, EI & Dorozhko, EV 2014, Electrochemical determination of heparin in pharmaceuticals with using malachite green. in Advanced Materials Research. vol. 1040, Advanced Materials Research, vol. 1040, Trans Tech Publications Ltd, pp. 292-296, International Conference for Young Scientists “High Technology: Research and Applications 2014”, HTRA 2014, Tomsk, Russian Federation, 26.3.14. https://doi.org/10.4028/www.scientific.net/AMR.1040.292
Vishenkova DA, Korotkova EI, Dorozhko EV. Electrochemical determination of heparin in pharmaceuticals with using malachite green. In Advanced Materials Research. Vol. 1040. Trans Tech Publications Ltd. 2014. p. 292-296. (Advanced Materials Research). https://doi.org/10.4028/www.scientific.net/AMR.1040.292
Vishenkova, D. A. ; Korotkova, E. I. ; Dorozhko, E. V. / Electrochemical determination of heparin in pharmaceuticals with using malachite green. Advanced Materials Research. Vol. 1040 Trans Tech Publications Ltd, 2014. pp. 292-296 (Advanced Materials Research).
@inproceedings{23cfe844acc64ac7b301acf69405b840,
title = "Electrochemical determination of heparin in pharmaceuticals with using malachite green",
abstract = "In this paper for determination of heparin in pharmaceuticals by constant-current sweep voltammetry on the mercury-film electrode (MFE) we used cationic malachite green (MG) dye which is capable to form a complex with heparin. In the 0.05 M potassium tetraoxalate (KH3C4O8 · 2H2O) buffer solution with pH 1.65 MG had a well-defined peak of electroreduction at -0.46 V (vs. CSE). During the study of electrochemical properties of heparin in complex with MG in cathodic potential range from 0.0 V to -1.3 V on MFE besides the signal from the dye at E = - 0.46 V the second signal at E = –0.87 V was found. Increasing the concentration of heparin in the solution led to decrease of signal intensity at E = -0.87 V. Optimum conditions for the electrochemical determination of heparin in dosage form with using MG were picked up. Influence of auxiliary components of heparin pharmacological solution on electroreduction of the complex MG-Hep was investigated. Under optimal conditions the decrease of reduction peak currents at E = -0.87 V was proportional to heparin concentration in the range from 3.9 · 10-4 mg/ml to 3.9 · 10-3 mg/ml.",
keywords = "Electroreduction, Heparin, Malachite green, Mercury-film electrode, Voltammetry",
author = "Vishenkova, {D. A.} and Korotkova, {E. I.} and Dorozhko, {E. V.}",
year = "2014",
doi = "10.4028/www.scientific.net/AMR.1040.292",
language = "English",
isbn = "9783038352648",
volume = "1040",
series = "Advanced Materials Research",
publisher = "Trans Tech Publications Ltd",
pages = "292--296",
booktitle = "Advanced Materials Research",

}

TY - GEN

T1 - Electrochemical determination of heparin in pharmaceuticals with using malachite green

AU - Vishenkova, D. A.

AU - Korotkova, E. I.

AU - Dorozhko, E. V.

PY - 2014

Y1 - 2014

N2 - In this paper for determination of heparin in pharmaceuticals by constant-current sweep voltammetry on the mercury-film electrode (MFE) we used cationic malachite green (MG) dye which is capable to form a complex with heparin. In the 0.05 M potassium tetraoxalate (KH3C4O8 · 2H2O) buffer solution with pH 1.65 MG had a well-defined peak of electroreduction at -0.46 V (vs. CSE). During the study of electrochemical properties of heparin in complex with MG in cathodic potential range from 0.0 V to -1.3 V on MFE besides the signal from the dye at E = - 0.46 V the second signal at E = –0.87 V was found. Increasing the concentration of heparin in the solution led to decrease of signal intensity at E = -0.87 V. Optimum conditions for the electrochemical determination of heparin in dosage form with using MG were picked up. Influence of auxiliary components of heparin pharmacological solution on electroreduction of the complex MG-Hep was investigated. Under optimal conditions the decrease of reduction peak currents at E = -0.87 V was proportional to heparin concentration in the range from 3.9 · 10-4 mg/ml to 3.9 · 10-3 mg/ml.

AB - In this paper for determination of heparin in pharmaceuticals by constant-current sweep voltammetry on the mercury-film electrode (MFE) we used cationic malachite green (MG) dye which is capable to form a complex with heparin. In the 0.05 M potassium tetraoxalate (KH3C4O8 · 2H2O) buffer solution with pH 1.65 MG had a well-defined peak of electroreduction at -0.46 V (vs. CSE). During the study of electrochemical properties of heparin in complex with MG in cathodic potential range from 0.0 V to -1.3 V on MFE besides the signal from the dye at E = - 0.46 V the second signal at E = –0.87 V was found. Increasing the concentration of heparin in the solution led to decrease of signal intensity at E = -0.87 V. Optimum conditions for the electrochemical determination of heparin in dosage form with using MG were picked up. Influence of auxiliary components of heparin pharmacological solution on electroreduction of the complex MG-Hep was investigated. Under optimal conditions the decrease of reduction peak currents at E = -0.87 V was proportional to heparin concentration in the range from 3.9 · 10-4 mg/ml to 3.9 · 10-3 mg/ml.

KW - Electroreduction

KW - Heparin

KW - Malachite green

KW - Mercury-film electrode

KW - Voltammetry

UR - http://www.scopus.com/inward/record.url?scp=84913594237&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84913594237&partnerID=8YFLogxK

U2 - 10.4028/www.scientific.net/AMR.1040.292

DO - 10.4028/www.scientific.net/AMR.1040.292

M3 - Conference contribution

SN - 9783038352648

VL - 1040

T3 - Advanced Materials Research

SP - 292

EP - 296

BT - Advanced Materials Research

PB - Trans Tech Publications Ltd

ER -