Dynamic mass analyzer of a new type

L. N. Gall, G. K. Golikov, Z. Z. Latypov, N. A. Timchenko

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The study presents results from numerical investigations aimed at developing a dynamic mass analyzer of a new type with more advanced analytical parameters. The mass analyzer consists of an ion source-converter and static energy analyzer of charged particles. Ion source converts ion mass differences into differences of their final energy. The spatial separation of the ions as well as the particle energy spectrum is obtained in the energy analyzer. This energy spectrum relates uniquely to the mass spectrum. Parameters of the mass analyzer are: operational mass range 1-1000u, relative resolution ~1000 and compatibility in the same device of methods of mass spectrometry and electron spectrometry for solving various research and technological problems.

Original languageEnglish
Pages (from-to)461-467
Number of pages7
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume423
Issue number2-3
DOIs
Publication statusPublished - 1 Mar 1999

Fingerprint

Ion sources
analyzers
Ions
Charged particles
Spectrometry
Mass spectrometry
ion sources
energy spectra
Electrons
particle energy
compatibility
mass spectra
converters
energy
charged particles
ions
mass spectroscopy
spectroscopy
electrons

Keywords

  • Charged ions
  • Dynamic mass analyzer
  • Ion source-converter

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Cite this

Dynamic mass analyzer of a new type. / Gall, L. N.; Golikov, G. K.; Latypov, Z. Z.; Timchenko, N. A.

In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 423, No. 2-3, 01.03.1999, p. 461-467.

Research output: Contribution to journalArticle

@article{0fb98c3fe6484697a85a8f3cdd13f0b7,
title = "Dynamic mass analyzer of a new type",
abstract = "The study presents results from numerical investigations aimed at developing a dynamic mass analyzer of a new type with more advanced analytical parameters. The mass analyzer consists of an ion source-converter and static energy analyzer of charged particles. Ion source converts ion mass differences into differences of their final energy. The spatial separation of the ions as well as the particle energy spectrum is obtained in the energy analyzer. This energy spectrum relates uniquely to the mass spectrum. Parameters of the mass analyzer are: operational mass range 1-1000u, relative resolution ~1000 and compatibility in the same device of methods of mass spectrometry and electron spectrometry for solving various research and technological problems.",
keywords = "Charged ions, Dynamic mass analyzer, Ion source-converter",
author = "Gall, {L. N.} and Golikov, {G. K.} and Latypov, {Z. Z.} and Timchenko, {N. A.}",
year = "1999",
month = "3",
day = "1",
doi = "10.1016/S0168-9002(98)01270-4",
language = "English",
volume = "423",
pages = "461--467",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "2-3",

}

TY - JOUR

T1 - Dynamic mass analyzer of a new type

AU - Gall, L. N.

AU - Golikov, G. K.

AU - Latypov, Z. Z.

AU - Timchenko, N. A.

PY - 1999/3/1

Y1 - 1999/3/1

N2 - The study presents results from numerical investigations aimed at developing a dynamic mass analyzer of a new type with more advanced analytical parameters. The mass analyzer consists of an ion source-converter and static energy analyzer of charged particles. Ion source converts ion mass differences into differences of their final energy. The spatial separation of the ions as well as the particle energy spectrum is obtained in the energy analyzer. This energy spectrum relates uniquely to the mass spectrum. Parameters of the mass analyzer are: operational mass range 1-1000u, relative resolution ~1000 and compatibility in the same device of methods of mass spectrometry and electron spectrometry for solving various research and technological problems.

AB - The study presents results from numerical investigations aimed at developing a dynamic mass analyzer of a new type with more advanced analytical parameters. The mass analyzer consists of an ion source-converter and static energy analyzer of charged particles. Ion source converts ion mass differences into differences of their final energy. The spatial separation of the ions as well as the particle energy spectrum is obtained in the energy analyzer. This energy spectrum relates uniquely to the mass spectrum. Parameters of the mass analyzer are: operational mass range 1-1000u, relative resolution ~1000 and compatibility in the same device of methods of mass spectrometry and electron spectrometry for solving various research and technological problems.

KW - Charged ions

KW - Dynamic mass analyzer

KW - Ion source-converter

UR - http://www.scopus.com/inward/record.url?scp=0033101069&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033101069&partnerID=8YFLogxK

U2 - 10.1016/S0168-9002(98)01270-4

DO - 10.1016/S0168-9002(98)01270-4

M3 - Article

AN - SCOPUS:0033101069

VL - 423

SP - 461

EP - 467

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 2-3

ER -