Drive signal waveform for a fluxgate

P. Baranov, V. Baranova, A. Kolomeytsev, I. Zatonov

Research output: Contribution to journalConference article

Abstract

One of the obvious applications of magnetometers is a system of magnetic vacuum which is able to minimize the influence of external magnetic fields on the operation of electronic instrumentation. In magnetic field systems, fluxgate magnetometers are commonly used in the capacity of absolute magnetic field sensors. However, the quality improvement of magnetic vacuum requires the improvement of the fluxgate performance, in particular, its sensitivity.

Original languageEnglish
Article number052020
JournalJournal of Physics: Conference Series
Volume1065
Issue number5
DOIs
Publication statusPublished - 13 Nov 2018
Event22nd World Congress of the International Measurement Confederation, IMEKO 2018 - Belfast, United Kingdom
Duration: 3 Sep 20186 Sep 2018

Fingerprint

waveforms
magnetometers
magnetic fields
vacuum
sensitivity
sensors
electronics

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Drive signal waveform for a fluxgate. / Baranov, P.; Baranova, V.; Kolomeytsev, A.; Zatonov, I.

In: Journal of Physics: Conference Series, Vol. 1065, No. 5, 052020, 13.11.2018.

Research output: Contribution to journalConference article

Baranov, P. ; Baranova, V. ; Kolomeytsev, A. ; Zatonov, I. / Drive signal waveform for a fluxgate. In: Journal of Physics: Conference Series. 2018 ; Vol. 1065, No. 5.
@article{a13214ecff8d42bba3737e6bdfe4daba,
title = "Drive signal waveform for a fluxgate",
abstract = "One of the obvious applications of magnetometers is a system of magnetic vacuum which is able to minimize the influence of external magnetic fields on the operation of electronic instrumentation. In magnetic field systems, fluxgate magnetometers are commonly used in the capacity of absolute magnetic field sensors. However, the quality improvement of magnetic vacuum requires the improvement of the fluxgate performance, in particular, its sensitivity.",
author = "P. Baranov and V. Baranova and A. Kolomeytsev and I. Zatonov",
year = "2018",
month = "11",
day = "13",
doi = "10.1088/1742-6596/1065/5/052020",
language = "English",
volume = "1065",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "5",

}

TY - JOUR

T1 - Drive signal waveform for a fluxgate

AU - Baranov, P.

AU - Baranova, V.

AU - Kolomeytsev, A.

AU - Zatonov, I.

PY - 2018/11/13

Y1 - 2018/11/13

N2 - One of the obvious applications of magnetometers is a system of magnetic vacuum which is able to minimize the influence of external magnetic fields on the operation of electronic instrumentation. In magnetic field systems, fluxgate magnetometers are commonly used in the capacity of absolute magnetic field sensors. However, the quality improvement of magnetic vacuum requires the improvement of the fluxgate performance, in particular, its sensitivity.

AB - One of the obvious applications of magnetometers is a system of magnetic vacuum which is able to minimize the influence of external magnetic fields on the operation of electronic instrumentation. In magnetic field systems, fluxgate magnetometers are commonly used in the capacity of absolute magnetic field sensors. However, the quality improvement of magnetic vacuum requires the improvement of the fluxgate performance, in particular, its sensitivity.

UR - http://www.scopus.com/inward/record.url?scp=85057442958&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85057442958&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/1065/5/052020

DO - 10.1088/1742-6596/1065/5/052020

M3 - Conference article

AN - SCOPUS:85057442958

VL - 1065

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 5

M1 - 052020

ER -