Direct Voltammetric Determination of Total Iron with a Gold Microelectrode Ensemble

E. A. Zakharova, E. E. Elesova, G. N. Noskova, M. Lu, R. G. Compton

    Research output: Contribution to journalArticle

    9 Citations (Scopus)

    Abstract

    The behavior of the Fe(II)/(III) redox system at a Au microelectrode ensemble (Au-MEE) based on a solid composite by means of direct and cyclic voltammetric analysis (VA) is reported. With a simple electrode activation and sample preparation, the influence of dissolved organic substances was eliminated, providing highly sensitive results. The analytical signal was based on the maximum cathodic current (I) of the first derivative (dI/dE), and iron determination within the 0.002-0.04mgL -1 range was studied. A sensitive LOD (3σ) value of 0.7μgL -1 for total iron concentration was calculated; total iron determination in different waters was shown.

    Original languageEnglish
    Pages (from-to)2061-2069
    Number of pages9
    JournalElectroanalysis
    Volume24
    Issue number11
    DOIs
    Publication statusPublished - 1 Nov 2012

    Fingerprint

    Microelectrodes
    Gold
    Iron
    Chemical activation
    Derivatives
    Electrodes
    Water
    Composite materials

    Keywords

    • Gold microelectrode ensemble
    • Iron
    • Microelectrodes
    • Voltammetric determination

    ASJC Scopus subject areas

    • Analytical Chemistry
    • Electrochemistry

    Cite this

    Zakharova, E. A., Elesova, E. E., Noskova, G. N., Lu, M., & Compton, R. G. (2012). Direct Voltammetric Determination of Total Iron with a Gold Microelectrode Ensemble. Electroanalysis, 24(11), 2061-2069. https://doi.org/10.1002/elan.201200417

    Direct Voltammetric Determination of Total Iron with a Gold Microelectrode Ensemble. / Zakharova, E. A.; Elesova, E. E.; Noskova, G. N.; Lu, M.; Compton, R. G.

    In: Electroanalysis, Vol. 24, No. 11, 01.11.2012, p. 2061-2069.

    Research output: Contribution to journalArticle

    Zakharova, EA, Elesova, EE, Noskova, GN, Lu, M & Compton, RG 2012, 'Direct Voltammetric Determination of Total Iron with a Gold Microelectrode Ensemble', Electroanalysis, vol. 24, no. 11, pp. 2061-2069. https://doi.org/10.1002/elan.201200417
    Zakharova, E. A. ; Elesova, E. E. ; Noskova, G. N. ; Lu, M. ; Compton, R. G. / Direct Voltammetric Determination of Total Iron with a Gold Microelectrode Ensemble. In: Electroanalysis. 2012 ; Vol. 24, No. 11. pp. 2061-2069.
    @article{78e3a5116e094a7d85ce1b5419daa5d9,
    title = "Direct Voltammetric Determination of Total Iron with a Gold Microelectrode Ensemble",
    abstract = "The behavior of the Fe(II)/(III) redox system at a Au microelectrode ensemble (Au-MEE) based on a solid composite by means of direct and cyclic voltammetric analysis (VA) is reported. With a simple electrode activation and sample preparation, the influence of dissolved organic substances was eliminated, providing highly sensitive results. The analytical signal was based on the maximum cathodic current (I) of the first derivative (dI/dE), and iron determination within the 0.002-0.04mgL -1 range was studied. A sensitive LOD (3σ) value of 0.7μgL -1 for total iron concentration was calculated; total iron determination in different waters was shown.",
    keywords = "Gold microelectrode ensemble, Iron, Microelectrodes, Voltammetric determination",
    author = "Zakharova, {E. A.} and Elesova, {E. E.} and Noskova, {G. N.} and M. Lu and Compton, {R. G.}",
    year = "2012",
    month = "11",
    day = "1",
    doi = "10.1002/elan.201200417",
    language = "English",
    volume = "24",
    pages = "2061--2069",
    journal = "Macromolecular Chemistry and Physics",
    issn = "1040-0397",
    publisher = "Wiley-VCH Verlag",
    number = "11",

    }

    TY - JOUR

    T1 - Direct Voltammetric Determination of Total Iron with a Gold Microelectrode Ensemble

    AU - Zakharova, E. A.

    AU - Elesova, E. E.

    AU - Noskova, G. N.

    AU - Lu, M.

    AU - Compton, R. G.

    PY - 2012/11/1

    Y1 - 2012/11/1

    N2 - The behavior of the Fe(II)/(III) redox system at a Au microelectrode ensemble (Au-MEE) based on a solid composite by means of direct and cyclic voltammetric analysis (VA) is reported. With a simple electrode activation and sample preparation, the influence of dissolved organic substances was eliminated, providing highly sensitive results. The analytical signal was based on the maximum cathodic current (I) of the first derivative (dI/dE), and iron determination within the 0.002-0.04mgL -1 range was studied. A sensitive LOD (3σ) value of 0.7μgL -1 for total iron concentration was calculated; total iron determination in different waters was shown.

    AB - The behavior of the Fe(II)/(III) redox system at a Au microelectrode ensemble (Au-MEE) based on a solid composite by means of direct and cyclic voltammetric analysis (VA) is reported. With a simple electrode activation and sample preparation, the influence of dissolved organic substances was eliminated, providing highly sensitive results. The analytical signal was based on the maximum cathodic current (I) of the first derivative (dI/dE), and iron determination within the 0.002-0.04mgL -1 range was studied. A sensitive LOD (3σ) value of 0.7μgL -1 for total iron concentration was calculated; total iron determination in different waters was shown.

    KW - Gold microelectrode ensemble

    KW - Iron

    KW - Microelectrodes

    KW - Voltammetric determination

    UR - http://www.scopus.com/inward/record.url?scp=84868592140&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84868592140&partnerID=8YFLogxK

    U2 - 10.1002/elan.201200417

    DO - 10.1002/elan.201200417

    M3 - Article

    AN - SCOPUS:84868592140

    VL - 24

    SP - 2061

    EP - 2069

    JO - Macromolecular Chemistry and Physics

    JF - Macromolecular Chemistry and Physics

    SN - 1040-0397

    IS - 11

    ER -