Development and research of MOPA system laboratory model

Nikolai A. Vasnev, Vasiliy V. Vlasov, Maxim V. Trigub

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The MOPA system laboratory model based on CuBr-lasers is implemented. The selection of wavelength (510.6 nm) and (578.2 nm) is performed, power dependencies are obtained and described. The principle possibility of using implemented laboratory model for a power amplification and image obtaining by a bistatic laser monitor is demonstrated.

Original languageEnglish
Title of host publication2018 19th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices, EDM 2018 - Proceedings
PublisherIEEE Computer Society
Pages383-386
Number of pages4
Volume2018-July
ISBN (Print)9781538650219
DOIs
Publication statusPublished - 13 Aug 2018
Event19th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices, EDM 2018 - Erlagol, Altai, Russian Federation
Duration: 29 Jun 20183 Jul 2018

Conference

Conference19th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices, EDM 2018
CountryRussian Federation
CityErlagol, Altai
Period29.6.183.7.18

Fingerprint

research and development
Lasers
lasers
Amplification
monitors
Wavelength
wavelengths

Keywords

  • Amplification
  • Bistatic laser monitor
  • CuBr-laser
  • Digital control circuit
  • MOPA system

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Atomic and Molecular Physics, and Optics

Cite this

Vasnev, N. A., Vlasov, V. V., & Trigub, M. V. (2018). Development and research of MOPA system laboratory model. In 2018 19th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices, EDM 2018 - Proceedings (Vol. 2018-July, pp. 383-386). [8435035] IEEE Computer Society. https://doi.org/10.1109/EDM.2018.8435035

Development and research of MOPA system laboratory model. / Vasnev, Nikolai A.; Vlasov, Vasiliy V.; Trigub, Maxim V.

2018 19th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices, EDM 2018 - Proceedings. Vol. 2018-July IEEE Computer Society, 2018. p. 383-386 8435035.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Vasnev, NA, Vlasov, VV & Trigub, MV 2018, Development and research of MOPA system laboratory model. in 2018 19th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices, EDM 2018 - Proceedings. vol. 2018-July, 8435035, IEEE Computer Society, pp. 383-386, 19th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices, EDM 2018, Erlagol, Altai, Russian Federation, 29.6.18. https://doi.org/10.1109/EDM.2018.8435035
Vasnev NA, Vlasov VV, Trigub MV. Development and research of MOPA system laboratory model. In 2018 19th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices, EDM 2018 - Proceedings. Vol. 2018-July. IEEE Computer Society. 2018. p. 383-386. 8435035 https://doi.org/10.1109/EDM.2018.8435035
Vasnev, Nikolai A. ; Vlasov, Vasiliy V. ; Trigub, Maxim V. / Development and research of MOPA system laboratory model. 2018 19th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices, EDM 2018 - Proceedings. Vol. 2018-July IEEE Computer Society, 2018. pp. 383-386
@inproceedings{6d8ff664fdc2437d81b1567b105d8b30,
title = "Development and research of MOPA system laboratory model",
abstract = "The MOPA system laboratory model based on CuBr-lasers is implemented. The selection of wavelength (510.6 nm) and (578.2 nm) is performed, power dependencies are obtained and described. The principle possibility of using implemented laboratory model for a power amplification and image obtaining by a bistatic laser monitor is demonstrated.",
keywords = "Amplification, Bistatic laser monitor, CuBr-laser, Digital control circuit, MOPA system",
author = "Vasnev, {Nikolai A.} and Vlasov, {Vasiliy V.} and Trigub, {Maxim V.}",
year = "2018",
month = "8",
day = "13",
doi = "10.1109/EDM.2018.8435035",
language = "English",
isbn = "9781538650219",
volume = "2018-July",
pages = "383--386",
booktitle = "2018 19th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices, EDM 2018 - Proceedings",
publisher = "IEEE Computer Society",
address = "United States",

}

TY - GEN

T1 - Development and research of MOPA system laboratory model

AU - Vasnev, Nikolai A.

AU - Vlasov, Vasiliy V.

AU - Trigub, Maxim V.

PY - 2018/8/13

Y1 - 2018/8/13

N2 - The MOPA system laboratory model based on CuBr-lasers is implemented. The selection of wavelength (510.6 nm) and (578.2 nm) is performed, power dependencies are obtained and described. The principle possibility of using implemented laboratory model for a power amplification and image obtaining by a bistatic laser monitor is demonstrated.

AB - The MOPA system laboratory model based on CuBr-lasers is implemented. The selection of wavelength (510.6 nm) and (578.2 nm) is performed, power dependencies are obtained and described. The principle possibility of using implemented laboratory model for a power amplification and image obtaining by a bistatic laser monitor is demonstrated.

KW - Amplification

KW - Bistatic laser monitor

KW - CuBr-laser

KW - Digital control circuit

KW - MOPA system

UR - http://www.scopus.com/inward/record.url?scp=85052392313&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85052392313&partnerID=8YFLogxK

U2 - 10.1109/EDM.2018.8435035

DO - 10.1109/EDM.2018.8435035

M3 - Conference contribution

AN - SCOPUS:85052392313

SN - 9781538650219

VL - 2018-July

SP - 383

EP - 386

BT - 2018 19th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices, EDM 2018 - Proceedings

PB - IEEE Computer Society

ER -