Determination of the effective resistance of a plasma opening switch

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Experiments with a short-circuited load and an aluminum wire array with a varied initial resistance were performed by using a GIT-4 inductivc-energy-storage generator with a plasma opening switch. The dependences Rp(t) for this switch were calculated using a set of statistical data obtained in experiments. The effective resistance of the plasma opening switch (∼1.2 Ω) establishes in 70-100 ns and remains virtually constant for the subsequent time interval of 40-70 ns.

Original languageEnglish
Pages (from-to)79-81
Number of pages3
JournalInstruments and Experimental Techniques
Volume40
Issue number1
Publication statusPublished - Jan 1997
Externally publishedYes

ASJC Scopus subject areas

  • Engineering (miscellaneous)
  • Instrumentation

Fingerprint Dive into the research topics of 'Determination of the effective resistance of a plasma opening switch'. Together they form a unique fingerprint.