In the paper the dosimetric parameters measurement technique of the bremsstrahlung generated by betatron OB-4 is described. The radiation dose measurement results from the bremsstrahlung generated by betatron are shown. The depth dose distributions of the bremsstrahlung generated by betatron obtained with the help of the solid thermoluminescent detectors DTL-02 and the dosimeter UNIDOS E equipped with a PTW Farmer cylindrical ionization chamber type 30013 in the different environments (in the air, in the water and in the lead) are illustrated.