Compact cryogenic attachment for Mossbauer spectroscopy with microwave excitation

N. P. Didenko, G. P. Amelin, V. I. Zelentsov, V. L. Kaminskii, N. P. Fedorov, V. M. Fal'kovich

Research output: Contribution to journalArticle

Abstract

A compact cryogenic attachment is described that is placed on a standard helium Dewar flask and permits recording of Mossbauer spectra with excitation by millimeter-band radiation in the temperature range of 4.3-300°K. The design of the attachment allows operation with various gamma-radiation detectors in both horizontal and vertical Mossbauer measurement geometries and its placement in superconducting magnets with a large 'warm' zone.

Original languageEnglish
Pages (from-to)1045-1048
Number of pages4
JournalInstruments and experimental techniques New York
Volume31
Issue number4 pt 2
Publication statusPublished - Feb 1989

Fingerprint

Dewars
Radiation detectors
Superconducting magnets
Mossbauer spectroscopy
Gamma rays
Cryogenics
cryogenics
attachment
Helium
Microwaves
flasks
Radiation
microwaves
Geometry
radiation detectors
superconducting magnets
spectroscopy
excitation
recording
helium

ASJC Scopus subject areas

  • Engineering (miscellaneous)
  • Instrumentation

Cite this

Didenko, N. P., Amelin, G. P., Zelentsov, V. I., Kaminskii, V. L., Fedorov, N. P., & Fal'kovich, V. M. (1989). Compact cryogenic attachment for Mossbauer spectroscopy with microwave excitation. Instruments and experimental techniques New York, 31(4 pt 2), 1045-1048.

Compact cryogenic attachment for Mossbauer spectroscopy with microwave excitation. / Didenko, N. P.; Amelin, G. P.; Zelentsov, V. I.; Kaminskii, V. L.; Fedorov, N. P.; Fal'kovich, V. M.

In: Instruments and experimental techniques New York, Vol. 31, No. 4 pt 2, 02.1989, p. 1045-1048.

Research output: Contribution to journalArticle

Didenko, NP, Amelin, GP, Zelentsov, VI, Kaminskii, VL, Fedorov, NP & Fal'kovich, VM 1989, 'Compact cryogenic attachment for Mossbauer spectroscopy with microwave excitation', Instruments and experimental techniques New York, vol. 31, no. 4 pt 2, pp. 1045-1048.
Didenko NP, Amelin GP, Zelentsov VI, Kaminskii VL, Fedorov NP, Fal'kovich VM. Compact cryogenic attachment for Mossbauer spectroscopy with microwave excitation. Instruments and experimental techniques New York. 1989 Feb;31(4 pt 2):1045-1048.
Didenko, N. P. ; Amelin, G. P. ; Zelentsov, V. I. ; Kaminskii, V. L. ; Fedorov, N. P. ; Fal'kovich, V. M. / Compact cryogenic attachment for Mossbauer spectroscopy with microwave excitation. In: Instruments and experimental techniques New York. 1989 ; Vol. 31, No. 4 pt 2. pp. 1045-1048.
@article{fd712c2260e04086b084a6a24620e496,
title = "Compact cryogenic attachment for Mossbauer spectroscopy with microwave excitation",
abstract = "A compact cryogenic attachment is described that is placed on a standard helium Dewar flask and permits recording of Mossbauer spectra with excitation by millimeter-band radiation in the temperature range of 4.3-300°K. The design of the attachment allows operation with various gamma-radiation detectors in both horizontal and vertical Mossbauer measurement geometries and its placement in superconducting magnets with a large 'warm' zone.",
author = "Didenko, {N. P.} and Amelin, {G. P.} and Zelentsov, {V. I.} and Kaminskii, {V. L.} and Fedorov, {N. P.} and Fal'kovich, {V. M.}",
year = "1989",
month = "2",
language = "English",
volume = "31",
pages = "1045--1048",
journal = "Instruments and Experimental Techniques",
issn = "0020-4412",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "4 pt 2",

}

TY - JOUR

T1 - Compact cryogenic attachment for Mossbauer spectroscopy with microwave excitation

AU - Didenko, N. P.

AU - Amelin, G. P.

AU - Zelentsov, V. I.

AU - Kaminskii, V. L.

AU - Fedorov, N. P.

AU - Fal'kovich, V. M.

PY - 1989/2

Y1 - 1989/2

N2 - A compact cryogenic attachment is described that is placed on a standard helium Dewar flask and permits recording of Mossbauer spectra with excitation by millimeter-band radiation in the temperature range of 4.3-300°K. The design of the attachment allows operation with various gamma-radiation detectors in both horizontal and vertical Mossbauer measurement geometries and its placement in superconducting magnets with a large 'warm' zone.

AB - A compact cryogenic attachment is described that is placed on a standard helium Dewar flask and permits recording of Mossbauer spectra with excitation by millimeter-band radiation in the temperature range of 4.3-300°K. The design of the attachment allows operation with various gamma-radiation detectors in both horizontal and vertical Mossbauer measurement geometries and its placement in superconducting magnets with a large 'warm' zone.

UR - http://www.scopus.com/inward/record.url?scp=0024613344&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024613344&partnerID=8YFLogxK

M3 - Article

VL - 31

SP - 1045

EP - 1048

JO - Instruments and Experimental Techniques

JF - Instruments and Experimental Techniques

SN - 0020-4412

IS - 4 pt 2

ER -