Cherenkov Radiation in the Visible and Ultraviolet Spectral Ranges from 6-MeV Electrons Passing through a Quartz Plate

Research output: Contribution to journalArticle

Abstract

Cherenkov radiation and pulsed cathodoluminescence spectra in the ultraviolet, visible, and near infrared regions generated by a 6-MeV electron beam passing through GE-014 and KU1 quartz plates have been experimentally studied. The Cherenkov radiation spectrum has been recorded in the ultraviolet and visible regions and its change is shown at the variation of the angle between the plane of the plate and the direction of the electron beam. The data on the conditions of recording of the Cherenkov radiation spectra at the excitation of plane-parallel plates of quartz, sapphire, and diamond have been presented. It has been shown that the total internal reflection in the crystals with a high refractive index imposes certain conditions on the geometry of the output of Cherenkov radiation into vacuum at electron energies above 500 kev.

Original languageEnglish
Pages (from-to)564-568
Number of pages5
JournalJETP Letters
Volume109
Issue number9
DOIs
Publication statusPublished - 1 May 2019

Fingerprint

radiation spectra
quartz
electron beams
radiation
cathodoluminescence
parallel plates
sapphire
electrons
recording
diamonds
electron energy
refractivity
vacuum
output
geometry
excitation
crystals

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)

Cite this

@article{18e3f449db0d418aa6e76f8efbd33729,
title = "Cherenkov Radiation in the Visible and Ultraviolet Spectral Ranges from 6-MeV Electrons Passing through a Quartz Plate",
abstract = "Cherenkov radiation and pulsed cathodoluminescence spectra in the ultraviolet, visible, and near infrared regions generated by a 6-MeV electron beam passing through GE-014 and KU1 quartz plates have been experimentally studied. The Cherenkov radiation spectrum has been recorded in the ultraviolet and visible regions and its change is shown at the variation of the angle between the plane of the plate and the direction of the electron beam. The data on the conditions of recording of the Cherenkov radiation spectra at the excitation of plane-parallel plates of quartz, sapphire, and diamond have been presented. It has been shown that the total internal reflection in the crystals with a high refractive index imposes certain conditions on the geometry of the output of Cherenkov radiation into vacuum at electron energies above 500 kev.",
author = "Baksht, {E. Kh} and Vukolov, {A. V.} and Erofeev, {M. V.} and Naumenko, {G. A.} and Potylitsyn, {A. P.} and Tarasenko, {V. F.} and Burachenko, {A. G.} and Shevelev, {M. V.}",
year = "2019",
month = "5",
day = "1",
doi = "10.1134/S0021364019090078",
language = "English",
volume = "109",
pages = "564--568",
journal = "JETP Letters",
issn = "0021-3640",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "9",

}

TY - JOUR

T1 - Cherenkov Radiation in the Visible and Ultraviolet Spectral Ranges from 6-MeV Electrons Passing through a Quartz Plate

AU - Baksht, E. Kh

AU - Vukolov, A. V.

AU - Erofeev, M. V.

AU - Naumenko, G. A.

AU - Potylitsyn, A. P.

AU - Tarasenko, V. F.

AU - Burachenko, A. G.

AU - Shevelev, M. V.

PY - 2019/5/1

Y1 - 2019/5/1

N2 - Cherenkov radiation and pulsed cathodoluminescence spectra in the ultraviolet, visible, and near infrared regions generated by a 6-MeV electron beam passing through GE-014 and KU1 quartz plates have been experimentally studied. The Cherenkov radiation spectrum has been recorded in the ultraviolet and visible regions and its change is shown at the variation of the angle between the plane of the plate and the direction of the electron beam. The data on the conditions of recording of the Cherenkov radiation spectra at the excitation of plane-parallel plates of quartz, sapphire, and diamond have been presented. It has been shown that the total internal reflection in the crystals with a high refractive index imposes certain conditions on the geometry of the output of Cherenkov radiation into vacuum at electron energies above 500 kev.

AB - Cherenkov radiation and pulsed cathodoluminescence spectra in the ultraviolet, visible, and near infrared regions generated by a 6-MeV electron beam passing through GE-014 and KU1 quartz plates have been experimentally studied. The Cherenkov radiation spectrum has been recorded in the ultraviolet and visible regions and its change is shown at the variation of the angle between the plane of the plate and the direction of the electron beam. The data on the conditions of recording of the Cherenkov radiation spectra at the excitation of plane-parallel plates of quartz, sapphire, and diamond have been presented. It has been shown that the total internal reflection in the crystals with a high refractive index imposes certain conditions on the geometry of the output of Cherenkov radiation into vacuum at electron energies above 500 kev.

UR - http://www.scopus.com/inward/record.url?scp=85069200570&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85069200570&partnerID=8YFLogxK

U2 - 10.1134/S0021364019090078

DO - 10.1134/S0021364019090078

M3 - Article

VL - 109

SP - 564

EP - 568

JO - JETP Letters

JF - JETP Letters

SN - 0021-3640

IS - 9

ER -