Characteristics of large-area position-sensitive scintillation detectors

Yu V. Vasil'chenko, A. N. Gulida, G. N. Dudkin, V. N. Padalko

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

We describe a design and present results of the examination of the characteristics of five types of polymethyl-methacrylate-based large-area position-sensitive scintillation detectors differing in the way the light is extracted to the photomultiplier tubes (PMT), in dimensions (120 × 100 × 3 and 160 × 140 × 3 cm), in the light attenuation length in the scintillator, and in the type of PMTs used. To obtain the coordinates of the point where the particle traverses the scintillator, the PMT signal amplitudes were analyzed. The factors affecting the coordinate resolution of the detectors were studied. The detector with dimensions 160 × 140 × 3 cm has a coordinate resolution of 15 cm, a time resolution of 2.2 ns, and a detection efficiency of 0.995.

Original languageEnglish
Pages (from-to)176-182
Number of pages7
JournalInstruments and Experimental Techniques
Volume41
Issue number2
Publication statusPublished - 1998

Fingerprint

Scintillation counters
Photomultipliers
Phosphors
scintillation
photomultiplier tubes
Detectors
scintillation counters
detectors
Polymethyl methacrylates
polymethyl methacrylate
examination
attenuation

ASJC Scopus subject areas

  • Engineering (miscellaneous)
  • Instrumentation

Cite this

Characteristics of large-area position-sensitive scintillation detectors. / Vasil'chenko, Yu V.; Gulida, A. N.; Dudkin, G. N.; Padalko, V. N.

In: Instruments and Experimental Techniques, Vol. 41, No. 2, 1998, p. 176-182.

Research output: Contribution to journalArticle

@article{bfae3a4ffd6f4bbc95865893802216ec,
title = "Characteristics of large-area position-sensitive scintillation detectors",
abstract = "We describe a design and present results of the examination of the characteristics of five types of polymethyl-methacrylate-based large-area position-sensitive scintillation detectors differing in the way the light is extracted to the photomultiplier tubes (PMT), in dimensions (120 × 100 × 3 and 160 × 140 × 3 cm), in the light attenuation length in the scintillator, and in the type of PMTs used. To obtain the coordinates of the point where the particle traverses the scintillator, the PMT signal amplitudes were analyzed. The factors affecting the coordinate resolution of the detectors were studied. The detector with dimensions 160 × 140 × 3 cm has a coordinate resolution of 15 cm, a time resolution of 2.2 ns, and a detection efficiency of 0.995.",
author = "Vasil'chenko, {Yu V.} and Gulida, {A. N.} and Dudkin, {G. N.} and Padalko, {V. N.}",
year = "1998",
language = "English",
volume = "41",
pages = "176--182",
journal = "Instruments and Experimental Techniques",
issn = "0020-4412",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "2",

}

TY - JOUR

T1 - Characteristics of large-area position-sensitive scintillation detectors

AU - Vasil'chenko, Yu V.

AU - Gulida, A. N.

AU - Dudkin, G. N.

AU - Padalko, V. N.

PY - 1998

Y1 - 1998

N2 - We describe a design and present results of the examination of the characteristics of five types of polymethyl-methacrylate-based large-area position-sensitive scintillation detectors differing in the way the light is extracted to the photomultiplier tubes (PMT), in dimensions (120 × 100 × 3 and 160 × 140 × 3 cm), in the light attenuation length in the scintillator, and in the type of PMTs used. To obtain the coordinates of the point where the particle traverses the scintillator, the PMT signal amplitudes were analyzed. The factors affecting the coordinate resolution of the detectors were studied. The detector with dimensions 160 × 140 × 3 cm has a coordinate resolution of 15 cm, a time resolution of 2.2 ns, and a detection efficiency of 0.995.

AB - We describe a design and present results of the examination of the characteristics of five types of polymethyl-methacrylate-based large-area position-sensitive scintillation detectors differing in the way the light is extracted to the photomultiplier tubes (PMT), in dimensions (120 × 100 × 3 and 160 × 140 × 3 cm), in the light attenuation length in the scintillator, and in the type of PMTs used. To obtain the coordinates of the point where the particle traverses the scintillator, the PMT signal amplitudes were analyzed. The factors affecting the coordinate resolution of the detectors were studied. The detector with dimensions 160 × 140 × 3 cm has a coordinate resolution of 15 cm, a time resolution of 2.2 ns, and a detection efficiency of 0.995.

UR - http://www.scopus.com/inward/record.url?scp=27544497126&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=27544497126&partnerID=8YFLogxK

M3 - Article

VL - 41

SP - 176

EP - 182

JO - Instruments and Experimental Techniques

JF - Instruments and Experimental Techniques

SN - 0020-4412

IS - 2

ER -