CERENKOV SPECTROMETERS WITH A HIGH TIME RESOLUTION.

Yu N. Adishchev, G. N. Dudkin, V. N. Eponeshnikov, Yu V. Krechetov

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

The time and spectrometric characteristics of TF-1 and KRS-6 Cerenkov total-absorption spectrometers with radiators were investigated using a monochromatic electron beam of a pair magnetic gamma spectrometer. In the energy range 200-600 Mev an energy resolution of 25-15% was obtained for TF-1 and 24-14% for KRS-6; a time resolution of 2 pi equals 2-3. 5 nsec was obtained for both TF-1 and KRS-6. The time shift was less than 0. 5 nsec in the 100-800 Mev energy range. The effect of the reflecting radiator coating on the time and spectrometric characteristics was investigated.

Original languageEnglish
Title of host publicationInstrum Exp Tech
Pages714-715
Number of pages2
Volume18
Edition3 pt 1
Publication statusPublished - May 1975

Fingerprint

Radiators
Spectrometers
Electron beams
Coatings

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Adishchev, Y. N., Dudkin, G. N., Eponeshnikov, V. N., & Krechetov, Y. V. (1975). CERENKOV SPECTROMETERS WITH A HIGH TIME RESOLUTION. In Instrum Exp Tech (3 pt 1 ed., Vol. 18, pp. 714-715)

CERENKOV SPECTROMETERS WITH A HIGH TIME RESOLUTION. / Adishchev, Yu N.; Dudkin, G. N.; Eponeshnikov, V. N.; Krechetov, Yu V.

Instrum Exp Tech. Vol. 18 3 pt 1. ed. 1975. p. 714-715.

Research output: Chapter in Book/Report/Conference proceedingChapter

Adishchev, YN, Dudkin, GN, Eponeshnikov, VN & Krechetov, YV 1975, CERENKOV SPECTROMETERS WITH A HIGH TIME RESOLUTION. in Instrum Exp Tech. 3 pt 1 edn, vol. 18, pp. 714-715.
Adishchev YN, Dudkin GN, Eponeshnikov VN, Krechetov YV. CERENKOV SPECTROMETERS WITH A HIGH TIME RESOLUTION. In Instrum Exp Tech. 3 pt 1 ed. Vol. 18. 1975. p. 714-715
Adishchev, Yu N. ; Dudkin, G. N. ; Eponeshnikov, V. N. ; Krechetov, Yu V. / CERENKOV SPECTROMETERS WITH A HIGH TIME RESOLUTION. Instrum Exp Tech. Vol. 18 3 pt 1. ed. 1975. pp. 714-715
@inbook{626d656615564c609adec7b429cf8797,
title = "CERENKOV SPECTROMETERS WITH A HIGH TIME RESOLUTION.",
abstract = "The time and spectrometric characteristics of TF-1 and KRS-6 Cerenkov total-absorption spectrometers with radiators were investigated using a monochromatic electron beam of a pair magnetic gamma spectrometer. In the energy range 200-600 Mev an energy resolution of 25-15{\%} was obtained for TF-1 and 24-14{\%} for KRS-6; a time resolution of 2 pi equals 2-3. 5 nsec was obtained for both TF-1 and KRS-6. The time shift was less than 0. 5 nsec in the 100-800 Mev energy range. The effect of the reflecting radiator coating on the time and spectrometric characteristics was investigated.",
author = "Adishchev, {Yu N.} and Dudkin, {G. N.} and Eponeshnikov, {V. N.} and Krechetov, {Yu V.}",
year = "1975",
month = "5",
language = "English",
volume = "18",
pages = "714--715",
booktitle = "Instrum Exp Tech",
edition = "3 pt 1",

}

TY - CHAP

T1 - CERENKOV SPECTROMETERS WITH A HIGH TIME RESOLUTION.

AU - Adishchev, Yu N.

AU - Dudkin, G. N.

AU - Eponeshnikov, V. N.

AU - Krechetov, Yu V.

PY - 1975/5

Y1 - 1975/5

N2 - The time and spectrometric characteristics of TF-1 and KRS-6 Cerenkov total-absorption spectrometers with radiators were investigated using a monochromatic electron beam of a pair magnetic gamma spectrometer. In the energy range 200-600 Mev an energy resolution of 25-15% was obtained for TF-1 and 24-14% for KRS-6; a time resolution of 2 pi equals 2-3. 5 nsec was obtained for both TF-1 and KRS-6. The time shift was less than 0. 5 nsec in the 100-800 Mev energy range. The effect of the reflecting radiator coating on the time and spectrometric characteristics was investigated.

AB - The time and spectrometric characteristics of TF-1 and KRS-6 Cerenkov total-absorption spectrometers with radiators were investigated using a monochromatic electron beam of a pair magnetic gamma spectrometer. In the energy range 200-600 Mev an energy resolution of 25-15% was obtained for TF-1 and 24-14% for KRS-6; a time resolution of 2 pi equals 2-3. 5 nsec was obtained for both TF-1 and KRS-6. The time shift was less than 0. 5 nsec in the 100-800 Mev energy range. The effect of the reflecting radiator coating on the time and spectrometric characteristics was investigated.

UR - http://www.scopus.com/inward/record.url?scp=0016503640&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0016503640&partnerID=8YFLogxK

M3 - Chapter

VL - 18

SP - 714

EP - 715

BT - Instrum Exp Tech

ER -