Beam-size measurement with optical diffraction radiation at KEK accelerator test facility

Pavel Vladimirovich Karataev, Sakae Araki, Ryosuke Hamatsu, Hitoshi Hayano, Toshiya Muto, Gennady Naumenko, Alexander Potylitsyn, Nobuhiro Terunuma, Junji Urakawa

Research output: Contribution to journalArticle

83 Citations (Scopus)

Abstract

The optical diffraction radiation (ODR) was investigated from a slit target for noninvasive electron beam-size diagnostics at the KEK accelerator test facility. The beam-size effect onto the ODR angular pattern was observed and the sensitivity to the beam size as small as 14μm was achieved. The first incoherent ODR observation from a slit target. The beam-size effect onto the ODR angular pattern was investigated using a set of wire scanners to measure the beam size.

Original languageEnglish
Article number244802
JournalPhysical Review Letters
Volume93
Issue number24
DOIs
Publication statusPublished - 10 Dec 2004

Fingerprint

diffraction radiation
test facilities
accelerators
slits
scanners
wire
electron beams
sensitivity

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Beam-size measurement with optical diffraction radiation at KEK accelerator test facility. / Karataev, Pavel Vladimirovich; Araki, Sakae; Hamatsu, Ryosuke; Hayano, Hitoshi; Muto, Toshiya; Naumenko, Gennady; Potylitsyn, Alexander; Terunuma, Nobuhiro; Urakawa, Junji.

In: Physical Review Letters, Vol. 93, No. 24, 244802, 10.12.2004.

Research output: Contribution to journalArticle

Karataev, Pavel Vladimirovich ; Araki, Sakae ; Hamatsu, Ryosuke ; Hayano, Hitoshi ; Muto, Toshiya ; Naumenko, Gennady ; Potylitsyn, Alexander ; Terunuma, Nobuhiro ; Urakawa, Junji. / Beam-size measurement with optical diffraction radiation at KEK accelerator test facility. In: Physical Review Letters. 2004 ; Vol. 93, No. 24.
@article{d80628a0d999444ab6ffa447ca589d8f,
title = "Beam-size measurement with optical diffraction radiation at KEK accelerator test facility",
abstract = "The optical diffraction radiation (ODR) was investigated from a slit target for noninvasive electron beam-size diagnostics at the KEK accelerator test facility. The beam-size effect onto the ODR angular pattern was observed and the sensitivity to the beam size as small as 14μm was achieved. The first incoherent ODR observation from a slit target. The beam-size effect onto the ODR angular pattern was investigated using a set of wire scanners to measure the beam size.",
author = "Karataev, {Pavel Vladimirovich} and Sakae Araki and Ryosuke Hamatsu and Hitoshi Hayano and Toshiya Muto and Gennady Naumenko and Alexander Potylitsyn and Nobuhiro Terunuma and Junji Urakawa",
year = "2004",
month = "12",
day = "10",
doi = "10.1103/PhysRevLett.93.244802",
language = "English",
volume = "93",
journal = "Physical Review Letters",
issn = "0031-9007",
publisher = "American Physical Society",
number = "24",

}

TY - JOUR

T1 - Beam-size measurement with optical diffraction radiation at KEK accelerator test facility

AU - Karataev, Pavel Vladimirovich

AU - Araki, Sakae

AU - Hamatsu, Ryosuke

AU - Hayano, Hitoshi

AU - Muto, Toshiya

AU - Naumenko, Gennady

AU - Potylitsyn, Alexander

AU - Terunuma, Nobuhiro

AU - Urakawa, Junji

PY - 2004/12/10

Y1 - 2004/12/10

N2 - The optical diffraction radiation (ODR) was investigated from a slit target for noninvasive electron beam-size diagnostics at the KEK accelerator test facility. The beam-size effect onto the ODR angular pattern was observed and the sensitivity to the beam size as small as 14μm was achieved. The first incoherent ODR observation from a slit target. The beam-size effect onto the ODR angular pattern was investigated using a set of wire scanners to measure the beam size.

AB - The optical diffraction radiation (ODR) was investigated from a slit target for noninvasive electron beam-size diagnostics at the KEK accelerator test facility. The beam-size effect onto the ODR angular pattern was observed and the sensitivity to the beam size as small as 14μm was achieved. The first incoherent ODR observation from a slit target. The beam-size effect onto the ODR angular pattern was investigated using a set of wire scanners to measure the beam size.

UR - http://www.scopus.com/inward/record.url?scp=28044471448&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=28044471448&partnerID=8YFLogxK

U2 - 10.1103/PhysRevLett.93.244802

DO - 10.1103/PhysRevLett.93.244802

M3 - Article

AN - SCOPUS:28044471448

VL - 93

JO - Physical Review Letters

JF - Physical Review Letters

SN - 0031-9007

IS - 24

M1 - 244802

ER -