Backward transition radiation in EUV-region as a possible tool for beam diagnostics

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

In this paper we propose to use backward transition radiation in EUV region for micron and submicron beam diagnostics. We have carried out simulations of backward transition radiation characteristics in the EUV region for molybdenum target using two approaches. The simulation results show a good agreement for both approaches and are very promising for beam diagnostics purposes.

Original languageEnglish
Pages (from-to)567-569
Number of pages3
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume623
Issue number1
DOIs
Publication statusPublished - 1 Nov 2010

Keywords

  • Backward transition radiation
  • Beam diagnostics
  • EUV region

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Fingerprint Dive into the research topics of 'Backward transition radiation in EUV-region as a possible tool for beam diagnostics'. Together they form a unique fingerprint.