Adequacy criteria of models of the cargo inspection system with material discrimination option

S. Osipov, S. Chakhlov, O. Osipov, A. Shtein, J. Van

Research output: Contribution to journalConference article

1 Citation (Scopus)

Abstract

Generalized adequacy criteria for mathematical models in order to discriminate materials in X-ray inspection systems by the dual-energy method were developed. Two main approaches of the examination systems to produce the adequacy criteria by the final and the intermediate parameters of the dual-energy method were analyzed. The criteria were specified in respect to the discrimination by the effective atomic number and by the method of level functions. Experimental and theoretical estimates of the discrimination parameters of the test object constituents scanned by fan beams of X-ray radiation with the maximal energies of 4.5 and 9 MeV are given.

Original languageEnglish
Article number012010
JournalJournal of Physics: Conference Series
Volume671
Issue number1
DOIs
Publication statusPublished - 18 Jan 2016
Event3rd All-Russian Scientific and Practical Conference on Innovations in Non-Destructive Testing, SibTest 2015 - Altai, Russian Federation
Duration: 27 Jul 201531 Jul 2015

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Fingerprint Dive into the research topics of 'Adequacy criteria of models of the cargo inspection system with material discrimination option'. Together they form a unique fingerprint.

  • Cite this