A two-step system for compression of microwave pulses in series-coupled resonators

Research output: Contribution to journalArticlepeer-review

8 Citations (Scopus)

Abstract

A system for resonance compression of microwave pulses consists of two resonators connected in series: the first is a high-Q oversized resonator and the second is a single-mode cylindrical resonator. The time dependences of the field strength in the resonators during their excitation and the energy transfer at different values of the transfer coefficient have been determined for the 10-cm wavelength region. The results of experimental studies are presented. The output pulses are 3 ns in length and have a maximum pulse power of 1.2 GW.

Original languageEnglish
Pages (from-to)233-236
Number of pages4
JournalInstruments and Experimental Techniques
Volume50
Issue number2
DOIs
Publication statusPublished - Mar 2007

ASJC Scopus subject areas

  • Engineering (miscellaneous)
  • Instrumentation

Fingerprint Dive into the research topics of 'A two-step system for compression of microwave pulses in series-coupled resonators'. Together they form a unique fingerprint.