Abstract
A system for resonance compression of microwave pulses consists of two resonators connected in series: the first is a high-Q oversized resonator and the second is a single-mode cylindrical resonator. The time dependences of the field strength in the resonators during their excitation and the energy transfer at different values of the transfer coefficient have been determined for the 10-cm wavelength region. The results of experimental studies are presented. The output pulses are 3 ns in length and have a maximum pulse power of 1.2 GW.
Original language | English |
---|---|
Pages (from-to) | 233-236 |
Number of pages | 4 |
Journal | Instruments and Experimental Techniques |
Volume | 50 |
Issue number | 2 |
DOIs | |
Publication status | Published - Mar 2007 |
ASJC Scopus subject areas
- Engineering (miscellaneous)
- Instrumentation