A power supply for a technological installation

V. V. Red'ko, B. A. Baginskii

Research output: Contribution to journalArticle

Abstract

A voltage changer for the power supply of an ultrasonic piezoelectric transducer is designed on the basis of a resonance inverter. The output filter designed on the basis of a series-resonant circuit with parallel and series compensation ensures matching of the changer to the load. The changer ensures a load current of 0.5 A ± 10% within a wide range of the load resistance (from 50 to 400 Ω) at an input voltage of 220 V ± 15% with automatic tuning to the frequency of the load mechanical resonance. The changer output power is 100 W, and the output current is a sinusoid with a frequency of 22 ± 2 kHz.

Original languageEnglish
Pages (from-to)576-579
Number of pages4
JournalInstruments and Experimental Techniques
Volume43
Issue number4
Publication statusPublished - Jul 2000

Fingerprint

power supplies
installing
Resonant circuits
Ultrasonic transducers
Piezoelectric transducers
Electric potential
output
Tuning
resonant vibration
piezoelectric transducers
sine waves
electric potential
ultrasonics
tuning
filters
Compensation and Redress

ASJC Scopus subject areas

  • Engineering (miscellaneous)
  • Instrumentation

Cite this

A power supply for a technological installation. / Red'ko, V. V.; Baginskii, B. A.

In: Instruments and Experimental Techniques, Vol. 43, No. 4, 07.2000, p. 576-579.

Research output: Contribution to journalArticle

@article{0499424cc5ec43b899b694314efc6320,
title = "A power supply for a technological installation",
abstract = "A voltage changer for the power supply of an ultrasonic piezoelectric transducer is designed on the basis of a resonance inverter. The output filter designed on the basis of a series-resonant circuit with parallel and series compensation ensures matching of the changer to the load. The changer ensures a load current of 0.5 A ± 10{\%} within a wide range of the load resistance (from 50 to 400 Ω) at an input voltage of 220 V ± 15{\%} with automatic tuning to the frequency of the load mechanical resonance. The changer output power is 100 W, and the output current is a sinusoid with a frequency of 22 ± 2 kHz.",
author = "Red'ko, {V. V.} and Baginskii, {B. A.}",
year = "2000",
month = "7",
language = "English",
volume = "43",
pages = "576--579",
journal = "Instruments and Experimental Techniques",
issn = "0020-4412",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "4",

}

TY - JOUR

T1 - A power supply for a technological installation

AU - Red'ko, V. V.

AU - Baginskii, B. A.

PY - 2000/7

Y1 - 2000/7

N2 - A voltage changer for the power supply of an ultrasonic piezoelectric transducer is designed on the basis of a resonance inverter. The output filter designed on the basis of a series-resonant circuit with parallel and series compensation ensures matching of the changer to the load. The changer ensures a load current of 0.5 A ± 10% within a wide range of the load resistance (from 50 to 400 Ω) at an input voltage of 220 V ± 15% with automatic tuning to the frequency of the load mechanical resonance. The changer output power is 100 W, and the output current is a sinusoid with a frequency of 22 ± 2 kHz.

AB - A voltage changer for the power supply of an ultrasonic piezoelectric transducer is designed on the basis of a resonance inverter. The output filter designed on the basis of a series-resonant circuit with parallel and series compensation ensures matching of the changer to the load. The changer ensures a load current of 0.5 A ± 10% within a wide range of the load resistance (from 50 to 400 Ω) at an input voltage of 220 V ± 15% with automatic tuning to the frequency of the load mechanical resonance. The changer output power is 100 W, and the output current is a sinusoid with a frequency of 22 ± 2 kHz.

UR - http://www.scopus.com/inward/record.url?scp=27644445330&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=27644445330&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:27644445330

VL - 43

SP - 576

EP - 579

JO - Instruments and Experimental Techniques

JF - Instruments and Experimental Techniques

SN - 0020-4412

IS - 4

ER -