A pessimistic view of the energy auditing of building structures with the use of infrared thermography

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

It has been shown that the estimates obtained for the heat losses in buildings and structures with the use of infrared thermography can be accompanied by 30.0-100.0% error levels, thus dictating the necessity of revising the specified requirements for indoor-to-outdoor temperature drops.

Original languageEnglish
Pages (from-to)906-910
Number of pages5
JournalRussian Journal of Nondestructive Testing
Volume46
Issue number12
DOIs
Publication statusPublished - 1 Dec 2010

Fingerprint

Heat losses
heat
requirements
estimates
Temperature
temperature
energy

Keywords

  • buildings and structures
  • heat losses
  • infrared diagnostics
  • infrared thermography
  • temperature drop

ASJC Scopus subject areas

  • Materials Science(all)
  • Condensed Matter Physics
  • Mechanics of Materials
  • Mechanical Engineering

Cite this

@article{412c1045617a4627ba73b31d53c343f6,
title = "A pessimistic view of the energy auditing of building structures with the use of infrared thermography",
abstract = "It has been shown that the estimates obtained for the heat losses in buildings and structures with the use of infrared thermography can be accompanied by 30.0-100.0{\%} error levels, thus dictating the necessity of revising the specified requirements for indoor-to-outdoor temperature drops.",
keywords = "buildings and structures, heat losses, infrared diagnostics, infrared thermography, temperature drop",
author = "Vavilov, {V. P.}",
year = "2010",
month = "12",
day = "1",
doi = "10.1134/S1061830910120065",
language = "English",
volume = "46",
pages = "906--910",
journal = "Russian Journal of Nondestructive Testing",
issn = "1061-8309",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "12",

}

TY - JOUR

T1 - A pessimistic view of the energy auditing of building structures with the use of infrared thermography

AU - Vavilov, V. P.

PY - 2010/12/1

Y1 - 2010/12/1

N2 - It has been shown that the estimates obtained for the heat losses in buildings and structures with the use of infrared thermography can be accompanied by 30.0-100.0% error levels, thus dictating the necessity of revising the specified requirements for indoor-to-outdoor temperature drops.

AB - It has been shown that the estimates obtained for the heat losses in buildings and structures with the use of infrared thermography can be accompanied by 30.0-100.0% error levels, thus dictating the necessity of revising the specified requirements for indoor-to-outdoor temperature drops.

KW - buildings and structures

KW - heat losses

KW - infrared diagnostics

KW - infrared thermography

KW - temperature drop

UR - http://www.scopus.com/inward/record.url?scp=79955792621&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79955792621&partnerID=8YFLogxK

U2 - 10.1134/S1061830910120065

DO - 10.1134/S1061830910120065

M3 - Article

AN - SCOPUS:79955792621

VL - 46

SP - 906

EP - 910

JO - Russian Journal of Nondestructive Testing

JF - Russian Journal of Nondestructive Testing

SN - 1061-8309

IS - 12

ER -