A microwave pulse resonance compressor operating at a 20-khz pulse repetition rate

Research output: Contribution to journalArticle

Abstract

A microwave pulse resonance compressor whose operation is based on resonance electromagnetic field amplification and subsequent rapid energy extraction to a load is described. A block diagram of the experimental setup is given. Results of tests of an S-band microwave compressor operating at a pulse repetition rate of up to 20 kHz are presented. The half-power width of the output pulses was about 5 ns, and the pulse power was 50 kW.

Original languageEnglish
Pages (from-to)381-382
Number of pages2
JournalInstruments and Experimental Techniques
Volume42
Issue number3
Publication statusPublished - 1999

ASJC Scopus subject areas

  • Engineering (miscellaneous)
  • Instrumentation

Fingerprint Dive into the research topics of 'A microwave pulse resonance compressor operating at a 20-khz pulse repetition rate'. Together they form a unique fingerprint.