In this article we present a mammography unit design using a parametric x-radiation (PXR) source. We show that PXR can provide a fanned quasimonochromatic x-ray beam that can be used to obtain mammography images of higher contrast and lower dose than those obtained from a conventional x-ray system. Changing the Bragg angle of the PXR crystal with respect to the electron beam changes the photon energy, improves image quality, and minimizes dose. Monte Carlo computer simulations are given that show that the PXR source with a 5% bandwidth gives a figure of merit close to that of the ideal monoenergetic source and significantly higher than that of the filtered-x-ray-tube sources. In order to simultaneously obtain adequate flux and achieve bandwidths below 5%, we utilized an electron-beam energy of 35 MeV and an average current of 300 μA to 1 mA for 3 s (depending upon breast thickness and density). Slits after the PX radiator are used to define both the spatial distribution and the spectral bandwidth of the x-ray beam, which is scanned over the breast in approximately 3 s. A graphite crystal C (002) in the Laue geometry is utilized as the PX radiator. Lower electron-beam currents might be possible as higher efficiency PX or hybrid radiators become available.

Original languageEnglish
Pages (from-to)2159-2170
Number of pages12
JournalReview of Scientific Instruments
Volume72
Issue number4
DOIs
Publication statusPublished - Apr 2001

Fingerprint

Mammography
x ray sources
radiators
Radiators
electron beams
bandwidth
radiation sources
Radiation
Electron beams
X rays
breast
Bandwidth
Bragg angle
x ray tubes
dosage
x rays
radiation
beam currents
figure of merit
Crystals

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)
  • Instrumentation

Cite this

Piestrup, M. A., Wu, X., Kaplan, V. V., Uglov, S. R., Cremer, J. T., Rule, D. W., & Fiorito, R. B. (2001). A design of mammography units using a quasimonochromatic x-ray source. Review of Scientific Instruments, 72(4), 2159-2170. https://doi.org/10.1063/1.1350639

A design of mammography units using a quasimonochromatic x-ray source. / Piestrup, M. A.; Wu, Xizeng; Kaplan, V. V.; Uglov, S. R.; Cremer, J. T.; Rule, D. W.; Fiorito, R. B.

In: Review of Scientific Instruments, Vol. 72, No. 4, 04.2001, p. 2159-2170.

Research output: Contribution to journalArticle

Piestrup, MA, Wu, X, Kaplan, VV, Uglov, SR, Cremer, JT, Rule, DW & Fiorito, RB 2001, 'A design of mammography units using a quasimonochromatic x-ray source', Review of Scientific Instruments, vol. 72, no. 4, pp. 2159-2170. https://doi.org/10.1063/1.1350639
Piestrup, M. A. ; Wu, Xizeng ; Kaplan, V. V. ; Uglov, S. R. ; Cremer, J. T. ; Rule, D. W. ; Fiorito, R. B. / A design of mammography units using a quasimonochromatic x-ray source. In: Review of Scientific Instruments. 2001 ; Vol. 72, No. 4. pp. 2159-2170.
@article{ce14f203ae64474b882501c31e183599,
title = "A design of mammography units using a quasimonochromatic x-ray source",
abstract = "In this article we present a mammography unit design using a parametric x-radiation (PXR) source. We show that PXR can provide a fanned quasimonochromatic x-ray beam that can be used to obtain mammography images of higher contrast and lower dose than those obtained from a conventional x-ray system. Changing the Bragg angle of the PXR crystal with respect to the electron beam changes the photon energy, improves image quality, and minimizes dose. Monte Carlo computer simulations are given that show that the PXR source with a 5{\%} bandwidth gives a figure of merit close to that of the ideal monoenergetic source and significantly higher than that of the filtered-x-ray-tube sources. In order to simultaneously obtain adequate flux and achieve bandwidths below 5{\%}, we utilized an electron-beam energy of 35 MeV and an average current of 300 μA to 1 mA for 3 s (depending upon breast thickness and density). Slits after the PX radiator are used to define both the spatial distribution and the spectral bandwidth of the x-ray beam, which is scanned over the breast in approximately 3 s. A graphite crystal C (002) in the Laue geometry is utilized as the PX radiator. Lower electron-beam currents might be possible as higher efficiency PX or hybrid radiators become available.",
author = "Piestrup, {M. A.} and Xizeng Wu and Kaplan, {V. V.} and Uglov, {S. R.} and Cremer, {J. T.} and Rule, {D. W.} and Fiorito, {R. B.}",
year = "2001",
month = "4",
doi = "10.1063/1.1350639",
language = "English",
volume = "72",
pages = "2159--2170",
journal = "Review of Scientific Instruments",
issn = "0034-6748",
publisher = "American Institute of Physics Publising LLC",
number = "4",

}

TY - JOUR

T1 - A design of mammography units using a quasimonochromatic x-ray source

AU - Piestrup, M. A.

AU - Wu, Xizeng

AU - Kaplan, V. V.

AU - Uglov, S. R.

AU - Cremer, J. T.

AU - Rule, D. W.

AU - Fiorito, R. B.

PY - 2001/4

Y1 - 2001/4

N2 - In this article we present a mammography unit design using a parametric x-radiation (PXR) source. We show that PXR can provide a fanned quasimonochromatic x-ray beam that can be used to obtain mammography images of higher contrast and lower dose than those obtained from a conventional x-ray system. Changing the Bragg angle of the PXR crystal with respect to the electron beam changes the photon energy, improves image quality, and minimizes dose. Monte Carlo computer simulations are given that show that the PXR source with a 5% bandwidth gives a figure of merit close to that of the ideal monoenergetic source and significantly higher than that of the filtered-x-ray-tube sources. In order to simultaneously obtain adequate flux and achieve bandwidths below 5%, we utilized an electron-beam energy of 35 MeV and an average current of 300 μA to 1 mA for 3 s (depending upon breast thickness and density). Slits after the PX radiator are used to define both the spatial distribution and the spectral bandwidth of the x-ray beam, which is scanned over the breast in approximately 3 s. A graphite crystal C (002) in the Laue geometry is utilized as the PX radiator. Lower electron-beam currents might be possible as higher efficiency PX or hybrid radiators become available.

AB - In this article we present a mammography unit design using a parametric x-radiation (PXR) source. We show that PXR can provide a fanned quasimonochromatic x-ray beam that can be used to obtain mammography images of higher contrast and lower dose than those obtained from a conventional x-ray system. Changing the Bragg angle of the PXR crystal with respect to the electron beam changes the photon energy, improves image quality, and minimizes dose. Monte Carlo computer simulations are given that show that the PXR source with a 5% bandwidth gives a figure of merit close to that of the ideal monoenergetic source and significantly higher than that of the filtered-x-ray-tube sources. In order to simultaneously obtain adequate flux and achieve bandwidths below 5%, we utilized an electron-beam energy of 35 MeV and an average current of 300 μA to 1 mA for 3 s (depending upon breast thickness and density). Slits after the PX radiator are used to define both the spatial distribution and the spectral bandwidth of the x-ray beam, which is scanned over the breast in approximately 3 s. A graphite crystal C (002) in the Laue geometry is utilized as the PX radiator. Lower electron-beam currents might be possible as higher efficiency PX or hybrid radiators become available.

UR - http://www.scopus.com/inward/record.url?scp=0035303802&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035303802&partnerID=8YFLogxK

U2 - 10.1063/1.1350639

DO - 10.1063/1.1350639

M3 - Article

AN - SCOPUS:0035303802

VL - 72

SP - 2159

EP - 2170

JO - Review of Scientific Instruments

JF - Review of Scientific Instruments

SN - 0034-6748

IS - 4

ER -