A computer measurement of welding surge currents

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

This paper presents both the hardware and software for a system for the measurement of welding process electric parameters. The distinctive feature of the system is its application for control of the process of high-quality contact micro-welding of critical destination products, which is characterized by the pulse current in the range from 100A to 20kA and by the pulse duration from a few to hundreds of milliseconds. The system is portable and consists of the measuring coaxial shunt, oscilloscope and computer with software. Structure, modeling and main principles of constructing the system components are described. Its technical and metrological parameters are given.

Original languageEnglish
Pages (from-to)44-47
Number of pages4
JournalMeasurement and Control
Volume42
Issue number2
DOIs
Publication statusPublished - 1 Jan 2009

Fingerprint

Surge
Welding
welding
computer programs
oscilloscopes
shunts
hardware
pulse duration
Hardware
Software
Coaxial
Computer simulation
products
pulses
Contact
Modeling
Range of data

Keywords

  • Measuring current shunt
  • Pulse current
  • Welding

ASJC Scopus subject areas

  • Instrumentation
  • Control and Optimization
  • Applied Mathematics

Cite this

A computer measurement of welding surge currents. / Muravyov, Sergey V.; Borikov, Valery N.; Natalinova, Nataliya Mihajlovna.

In: Measurement and Control, Vol. 42, No. 2, 01.01.2009, p. 44-47.

Research output: Contribution to journalArticle

@article{528d63fb2334403d85dbec08c4310cad,
title = "A computer measurement of welding surge currents",
abstract = "This paper presents both the hardware and software for a system for the measurement of welding process electric parameters. The distinctive feature of the system is its application for control of the process of high-quality contact micro-welding of critical destination products, which is characterized by the pulse current in the range from 100A to 20kA and by the pulse duration from a few to hundreds of milliseconds. The system is portable and consists of the measuring coaxial shunt, oscilloscope and computer with software. Structure, modeling and main principles of constructing the system components are described. Its technical and metrological parameters are given.",
keywords = "Measuring current shunt, Pulse current, Welding",
author = "Muravyov, {Sergey V.} and Borikov, {Valery N.} and Natalinova, {Nataliya Mihajlovna}",
year = "2009",
month = "1",
day = "1",
doi = "10.1177/002029400904200202",
language = "English",
volume = "42",
pages = "44--47",
journal = "Measurement and Control",
issn = "0020-2940",
publisher = "SAGE Publications Inc.",
number = "2",

}

TY - JOUR

T1 - A computer measurement of welding surge currents

AU - Muravyov, Sergey V.

AU - Borikov, Valery N.

AU - Natalinova, Nataliya Mihajlovna

PY - 2009/1/1

Y1 - 2009/1/1

N2 - This paper presents both the hardware and software for a system for the measurement of welding process electric parameters. The distinctive feature of the system is its application for control of the process of high-quality contact micro-welding of critical destination products, which is characterized by the pulse current in the range from 100A to 20kA and by the pulse duration from a few to hundreds of milliseconds. The system is portable and consists of the measuring coaxial shunt, oscilloscope and computer with software. Structure, modeling and main principles of constructing the system components are described. Its technical and metrological parameters are given.

AB - This paper presents both the hardware and software for a system for the measurement of welding process electric parameters. The distinctive feature of the system is its application for control of the process of high-quality contact micro-welding of critical destination products, which is characterized by the pulse current in the range from 100A to 20kA and by the pulse duration from a few to hundreds of milliseconds. The system is portable and consists of the measuring coaxial shunt, oscilloscope and computer with software. Structure, modeling and main principles of constructing the system components are described. Its technical and metrological parameters are given.

KW - Measuring current shunt

KW - Pulse current

KW - Welding

UR - http://www.scopus.com/inward/record.url?scp=63049094826&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=63049094826&partnerID=8YFLogxK

U2 - 10.1177/002029400904200202

DO - 10.1177/002029400904200202

M3 - Article

AN - SCOPUS:63049094826

VL - 42

SP - 44

EP - 47

JO - Measurement and Control

JF - Measurement and Control

SN - 0020-2940

IS - 2

ER -