A compact high current generator for X-ray radiography

B. M. Kovalchuk, A. V. Kharlov, V. B. Zorin

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Abstract

    X-generator was designed for small scale experiments with imploding liners, especially X-pinches. The generator consists of the capacitor bank, multi-channel multi-gap spark switch, flat current buses, load chamber and built-in high voltage triggering generator. The capacitor bank consists of 12 General Atomics 35404 type capacitors (20 nF, 25nH, 0.2 Ohm, 100 kV). It stores ∼ 0.8 kJ at 80 kV charging voltage. Each three capacitors are commuted to a load by multi-gap spark switch, which is able to commute by 8 parallel channels. Switches operate in ambient air at atmospheric pressure. The X-generator was tested with 5 and 10.5 nH inductive loads. At 76 kV charging voltage the generator provides ∼260 kA with 120 ns risetime with 5 nH inductive load and ∼220 kA with 145 ns risetime with 10.5 nH. Delay of output pulse relatively to high voltage triggering pulse was 65 ns with 5 ns jitter ( at 76 kV charging voltage). Dimensions of the generator are 1240×1240×225 mm 3 and weight is ∼ 250 kg, so it could be easily employed for variety of applications.

    Original languageEnglish
    Title of host publicationDigest of Technical Papers-IEEE International Pulsed Power Conference
    Pages1314-1317
    Number of pages4
    DOIs
    Publication statusPublished - 2007
    Event2005 IEEE Pulsed Power Conference, PPC - Monterey, CA, United States
    Duration: 13 Jun 200517 Jun 2005

    Other

    Other2005 IEEE Pulsed Power Conference, PPC
    CountryUnited States
    CityMonterey, CA
    Period13.6.0517.6.05

    Fingerprint

    X ray radiography
    Capacitors
    Electric potential
    Switches
    Electric sparks
    Jitter
    Atmospheric pressure
    Air
    Experiments

    ASJC Scopus subject areas

    • Electrical and Electronic Engineering

    Cite this

    Kovalchuk, B. M., Kharlov, A. V., & Zorin, V. B. (2007). A compact high current generator for X-ray radiography. In Digest of Technical Papers-IEEE International Pulsed Power Conference (pp. 1314-1317). [4084468] https://doi.org/10.1109/PPC.2005.300614

    A compact high current generator for X-ray radiography. / Kovalchuk, B. M.; Kharlov, A. V.; Zorin, V. B.

    Digest of Technical Papers-IEEE International Pulsed Power Conference. 2007. p. 1314-1317 4084468.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Kovalchuk, BM, Kharlov, AV & Zorin, VB 2007, A compact high current generator for X-ray radiography. in Digest of Technical Papers-IEEE International Pulsed Power Conference., 4084468, pp. 1314-1317, 2005 IEEE Pulsed Power Conference, PPC, Monterey, CA, United States, 13.6.05. https://doi.org/10.1109/PPC.2005.300614
    Kovalchuk BM, Kharlov AV, Zorin VB. A compact high current generator for X-ray radiography. In Digest of Technical Papers-IEEE International Pulsed Power Conference. 2007. p. 1314-1317. 4084468 https://doi.org/10.1109/PPC.2005.300614
    Kovalchuk, B. M. ; Kharlov, A. V. ; Zorin, V. B. / A compact high current generator for X-ray radiography. Digest of Technical Papers-IEEE International Pulsed Power Conference. 2007. pp. 1314-1317
    @inproceedings{a738d29cdf48414abc23646d96276343,
    title = "A compact high current generator for X-ray radiography",
    abstract = "X-generator was designed for small scale experiments with imploding liners, especially X-pinches. The generator consists of the capacitor bank, multi-channel multi-gap spark switch, flat current buses, load chamber and built-in high voltage triggering generator. The capacitor bank consists of 12 General Atomics 35404 type capacitors (20 nF, 25nH, 0.2 Ohm, 100 kV). It stores ∼ 0.8 kJ at 80 kV charging voltage. Each three capacitors are commuted to a load by multi-gap spark switch, which is able to commute by 8 parallel channels. Switches operate in ambient air at atmospheric pressure. The X-generator was tested with 5 and 10.5 nH inductive loads. At 76 kV charging voltage the generator provides ∼260 kA with 120 ns risetime with 5 nH inductive load and ∼220 kA with 145 ns risetime with 10.5 nH. Delay of output pulse relatively to high voltage triggering pulse was 65 ns with 5 ns jitter ( at 76 kV charging voltage). Dimensions of the generator are 1240×1240×225 mm 3 and weight is ∼ 250 kg, so it could be easily employed for variety of applications.",
    author = "Kovalchuk, {B. M.} and Kharlov, {A. V.} and Zorin, {V. B.}",
    year = "2007",
    doi = "10.1109/PPC.2005.300614",
    language = "English",
    isbn = "078039190X",
    pages = "1314--1317",
    booktitle = "Digest of Technical Papers-IEEE International Pulsed Power Conference",

    }

    TY - GEN

    T1 - A compact high current generator for X-ray radiography

    AU - Kovalchuk, B. M.

    AU - Kharlov, A. V.

    AU - Zorin, V. B.

    PY - 2007

    Y1 - 2007

    N2 - X-generator was designed for small scale experiments with imploding liners, especially X-pinches. The generator consists of the capacitor bank, multi-channel multi-gap spark switch, flat current buses, load chamber and built-in high voltage triggering generator. The capacitor bank consists of 12 General Atomics 35404 type capacitors (20 nF, 25nH, 0.2 Ohm, 100 kV). It stores ∼ 0.8 kJ at 80 kV charging voltage. Each three capacitors are commuted to a load by multi-gap spark switch, which is able to commute by 8 parallel channels. Switches operate in ambient air at atmospheric pressure. The X-generator was tested with 5 and 10.5 nH inductive loads. At 76 kV charging voltage the generator provides ∼260 kA with 120 ns risetime with 5 nH inductive load and ∼220 kA with 145 ns risetime with 10.5 nH. Delay of output pulse relatively to high voltage triggering pulse was 65 ns with 5 ns jitter ( at 76 kV charging voltage). Dimensions of the generator are 1240×1240×225 mm 3 and weight is ∼ 250 kg, so it could be easily employed for variety of applications.

    AB - X-generator was designed for small scale experiments with imploding liners, especially X-pinches. The generator consists of the capacitor bank, multi-channel multi-gap spark switch, flat current buses, load chamber and built-in high voltage triggering generator. The capacitor bank consists of 12 General Atomics 35404 type capacitors (20 nF, 25nH, 0.2 Ohm, 100 kV). It stores ∼ 0.8 kJ at 80 kV charging voltage. Each three capacitors are commuted to a load by multi-gap spark switch, which is able to commute by 8 parallel channels. Switches operate in ambient air at atmospheric pressure. The X-generator was tested with 5 and 10.5 nH inductive loads. At 76 kV charging voltage the generator provides ∼260 kA with 120 ns risetime with 5 nH inductive load and ∼220 kA with 145 ns risetime with 10.5 nH. Delay of output pulse relatively to high voltage triggering pulse was 65 ns with 5 ns jitter ( at 76 kV charging voltage). Dimensions of the generator are 1240×1240×225 mm 3 and weight is ∼ 250 kg, so it could be easily employed for variety of applications.

    UR - http://www.scopus.com/inward/record.url?scp=45149099065&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=45149099065&partnerID=8YFLogxK

    U2 - 10.1109/PPC.2005.300614

    DO - 10.1109/PPC.2005.300614

    M3 - Conference contribution

    SN - 078039190X

    SN - 9780780391901

    SP - 1314

    EP - 1317

    BT - Digest of Technical Papers-IEEE International Pulsed Power Conference

    ER -