660 keV gamma-quanta counter based on multichannel GaAs detector

A. N. Zarubin, A. V. Tyazhev, Irena Felixovna Nam, S. A. Ryabkov, M. A. Rozhnev

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Results obtained from development, testing, and evaluation of 660 keV gamma-quantum counter based on multichannel GaAs detector are presented. The counter operated in quantum count mode and counting rate up to 1000 quanta/(s·cm3) have been demonstrated for 30cm distance between detector and 660 keV gamma-quanta source.

Original languageEnglish
Title of host publicationIEEE International Siberian Conference on Control and Communications, SIBCON-2007; Proceedings
Pages239-242
Number of pages4
DOIs
Publication statusPublished - 2007
Externally publishedYes
EventIEEE International Siberian Conference on Control and Communications, SIBCON-2007 - Tomsk, Russian Federation
Duration: 20 Apr 200721 Apr 2007

Conference

ConferenceIEEE International Siberian Conference on Control and Communications, SIBCON-2007
CountryRussian Federation
CityTomsk
Period20.4.0721.4.07

Fingerprint

Detectors
evaluation
Testing

Keywords

  • ASIC
  • Counter
  • Detector
  • GaAs
  • Gamma-quantum

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Electrical and Electronic Engineering
  • Communication

Cite this

Zarubin, A. N., Tyazhev, A. V., Nam, I. F., Ryabkov, S. A., & Rozhnev, M. A. (2007). 660 keV gamma-quanta counter based on multichannel GaAs detector. In IEEE International Siberian Conference on Control and Communications, SIBCON-2007; Proceedings (pp. 239-242). [4233314] https://doi.org/10.1109/SIBCON.2007.371335

660 keV gamma-quanta counter based on multichannel GaAs detector. / Zarubin, A. N.; Tyazhev, A. V.; Nam, Irena Felixovna; Ryabkov, S. A.; Rozhnev, M. A.

IEEE International Siberian Conference on Control and Communications, SIBCON-2007; Proceedings. 2007. p. 239-242 4233314.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Zarubin, AN, Tyazhev, AV, Nam, IF, Ryabkov, SA & Rozhnev, MA 2007, 660 keV gamma-quanta counter based on multichannel GaAs detector. in IEEE International Siberian Conference on Control and Communications, SIBCON-2007; Proceedings., 4233314, pp. 239-242, IEEE International Siberian Conference on Control and Communications, SIBCON-2007, Tomsk, Russian Federation, 20.4.07. https://doi.org/10.1109/SIBCON.2007.371335
Zarubin AN, Tyazhev AV, Nam IF, Ryabkov SA, Rozhnev MA. 660 keV gamma-quanta counter based on multichannel GaAs detector. In IEEE International Siberian Conference on Control and Communications, SIBCON-2007; Proceedings. 2007. p. 239-242. 4233314 https://doi.org/10.1109/SIBCON.2007.371335
Zarubin, A. N. ; Tyazhev, A. V. ; Nam, Irena Felixovna ; Ryabkov, S. A. ; Rozhnev, M. A. / 660 keV gamma-quanta counter based on multichannel GaAs detector. IEEE International Siberian Conference on Control and Communications, SIBCON-2007; Proceedings. 2007. pp. 239-242
@inproceedings{1112b97f4ab64abbb9c2e718998bc67b,
title = "660 keV gamma-quanta counter based on multichannel GaAs detector",
abstract = "Results obtained from development, testing, and evaluation of 660 keV gamma-quantum counter based on multichannel GaAs detector are presented. The counter operated in quantum count mode and counting rate up to 1000 quanta/(s·cm3) have been demonstrated for 30cm distance between detector and 660 keV gamma-quanta source.",
keywords = "ASIC, Counter, Detector, GaAs, Gamma-quantum",
author = "Zarubin, {A. N.} and Tyazhev, {A. V.} and Nam, {Irena Felixovna} and Ryabkov, {S. A.} and Rozhnev, {M. A.}",
year = "2007",
doi = "10.1109/SIBCON.2007.371335",
language = "English",
isbn = "1424403464",
pages = "239--242",
booktitle = "IEEE International Siberian Conference on Control and Communications, SIBCON-2007; Proceedings",

}

TY - GEN

T1 - 660 keV gamma-quanta counter based on multichannel GaAs detector

AU - Zarubin, A. N.

AU - Tyazhev, A. V.

AU - Nam, Irena Felixovna

AU - Ryabkov, S. A.

AU - Rozhnev, M. A.

PY - 2007

Y1 - 2007

N2 - Results obtained from development, testing, and evaluation of 660 keV gamma-quantum counter based on multichannel GaAs detector are presented. The counter operated in quantum count mode and counting rate up to 1000 quanta/(s·cm3) have been demonstrated for 30cm distance between detector and 660 keV gamma-quanta source.

AB - Results obtained from development, testing, and evaluation of 660 keV gamma-quantum counter based on multichannel GaAs detector are presented. The counter operated in quantum count mode and counting rate up to 1000 quanta/(s·cm3) have been demonstrated for 30cm distance between detector and 660 keV gamma-quanta source.

KW - ASIC

KW - Counter

KW - Detector

KW - GaAs

KW - Gamma-quantum

UR - http://www.scopus.com/inward/record.url?scp=34548843615&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34548843615&partnerID=8YFLogxK

U2 - 10.1109/SIBCON.2007.371335

DO - 10.1109/SIBCON.2007.371335

M3 - Conference contribution

AN - SCOPUS:34548843615

SN - 1424403464

SN - 9781424403462

SP - 239

EP - 242

BT - IEEE International Siberian Conference on Control and Communications, SIBCON-2007; Proceedings

ER -