6. 5-MeV MICROTRON WITH EXTERNAL INJECTION.

E. G. Gal', V. N. Eponeshnikov, N. A. Lashuk

    Research output: Contribution to journalArticle

    Abstract

    The microtron with external injection is intended for use as an injector of polarized electrons into a synchrotron and for solid-state research. A septum magnet, joined to ferromagnetic channels, is used to introduce the beam into the microtron. Injection into the resonator takes place near its axis. We demonstrate that acceleration is possible during modeling with unpolarized electrons. A current of 20 mA was obtained in a pulse at an energy of 6. 5 MeV and a capture coefficient of 10%.

    Original languageEnglish
    Pages (from-to)18-21
    Number of pages4
    JournalInstruments and experimental techniques New York
    Volume28
    Issue number1 pt 1
    Publication statusPublished - Jan 1985

    Fingerprint

    injection
    septum
    Electrons
    Synchrotrons
    injectors
    Magnets
    Resonators
    synchrotrons
    electrons
    magnets
    resonators
    solid state
    coefficients
    pulses
    energy

    ASJC Scopus subject areas

    • Engineering (miscellaneous)
    • Instrumentation

    Cite this

    Gal', E. G., Eponeshnikov, V. N., & Lashuk, N. A. (1985). 6. 5-MeV MICROTRON WITH EXTERNAL INJECTION. Instruments and experimental techniques New York, 28(1 pt 1), 18-21.

    6. 5-MeV MICROTRON WITH EXTERNAL INJECTION. / Gal', E. G.; Eponeshnikov, V. N.; Lashuk, N. A.

    In: Instruments and experimental techniques New York, Vol. 28, No. 1 pt 1, 01.1985, p. 18-21.

    Research output: Contribution to journalArticle

    Gal', EG, Eponeshnikov, VN & Lashuk, NA 1985, '6. 5-MeV MICROTRON WITH EXTERNAL INJECTION.', Instruments and experimental techniques New York, vol. 28, no. 1 pt 1, pp. 18-21.
    Gal' EG, Eponeshnikov VN, Lashuk NA. 6. 5-MeV MICROTRON WITH EXTERNAL INJECTION. Instruments and experimental techniques New York. 1985 Jan;28(1 pt 1):18-21.
    Gal', E. G. ; Eponeshnikov, V. N. ; Lashuk, N. A. / 6. 5-MeV MICROTRON WITH EXTERNAL INJECTION. In: Instruments and experimental techniques New York. 1985 ; Vol. 28, No. 1 pt 1. pp. 18-21.
    @article{d675c47a08944fa8b5f577c462ce809a,
    title = "6. 5-MeV MICROTRON WITH EXTERNAL INJECTION.",
    abstract = "The microtron with external injection is intended for use as an injector of polarized electrons into a synchrotron and for solid-state research. A septum magnet, joined to ferromagnetic channels, is used to introduce the beam into the microtron. Injection into the resonator takes place near its axis. We demonstrate that acceleration is possible during modeling with unpolarized electrons. A current of 20 mA was obtained in a pulse at an energy of 6. 5 MeV and a capture coefficient of 10{\%}.",
    author = "Gal', {E. G.} and Eponeshnikov, {V. N.} and Lashuk, {N. A.}",
    year = "1985",
    month = "1",
    language = "English",
    volume = "28",
    pages = "18--21",
    journal = "Instruments and Experimental Techniques",
    issn = "0020-4412",
    publisher = "Maik Nauka-Interperiodica Publishing",
    number = "1 pt 1",

    }

    TY - JOUR

    T1 - 6. 5-MeV MICROTRON WITH EXTERNAL INJECTION.

    AU - Gal', E. G.

    AU - Eponeshnikov, V. N.

    AU - Lashuk, N. A.

    PY - 1985/1

    Y1 - 1985/1

    N2 - The microtron with external injection is intended for use as an injector of polarized electrons into a synchrotron and for solid-state research. A septum magnet, joined to ferromagnetic channels, is used to introduce the beam into the microtron. Injection into the resonator takes place near its axis. We demonstrate that acceleration is possible during modeling with unpolarized electrons. A current of 20 mA was obtained in a pulse at an energy of 6. 5 MeV and a capture coefficient of 10%.

    AB - The microtron with external injection is intended for use as an injector of polarized electrons into a synchrotron and for solid-state research. A septum magnet, joined to ferromagnetic channels, is used to introduce the beam into the microtron. Injection into the resonator takes place near its axis. We demonstrate that acceleration is possible during modeling with unpolarized electrons. A current of 20 mA was obtained in a pulse at an energy of 6. 5 MeV and a capture coefficient of 10%.

    UR - http://www.scopus.com/inward/record.url?scp=0021899269&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0021899269&partnerID=8YFLogxK

    M3 - Article

    AN - SCOPUS:0021899269

    VL - 28

    SP - 18

    EP - 21

    JO - Instruments and Experimental Techniques

    JF - Instruments and Experimental Techniques

    SN - 0020-4412

    IS - 1 pt 1

    ER -